6.6 STORAGE
7
TROUBLESHOOTING
PROBLEM / SYMPTOM
If engine doesn't start,
check that:
If engine starts but there is
no power at receptacles,
check that:
If engine starts but runs
erratically, check that:
PORTABLE GENERATOR
Before storing the generator for a long period of time days.
1.
Close the fuel valve and remove and empty the sediment cup or fuel strainer.
2.
Disconnect the fuel line from the carburetor. Place the open end of the fuel line
into a suitable container and open the fuel valve to drain the fuel from the tank.
WARNING:
Gasoline is extremely flammable. Drain the fuel tank in a well-ventilated area. Do not
drain the fuel tank in an area with flames or sparks.
3.
Loosen the drain screw on the carburetor and drain any remaining fuel from the
carburetor.
4.
Change the engine oil.
5.
Remove the spark plug and pour approximately 30 ml (1 ounce) of clean engine
oil into the cylinder. Crank the engine a few turns to distribute the oil to the inside
of the cylinder walls.
6.
Pull the starter rope slowly until resistance is felt and leave the handle in this
position. This ensures that the intake and exhaust valves are closed.
7.
Store the generator in a clean, dry area.
REASON / REMEDY
▪ Engine switch is on "Start".
▪ Fuel valves under fuel tank and on engine are
▪ Fuel tank has fuel.
▪ Choke lever is in correct position. Choke should
▪ All loads are disconnected from generator.
▪ Spark plug is in good condition.
▪ Spark plug cap is tight.
▪ Engine oil level is adequate
▪ Circuit breaker is closed.
▪ Connector from generator to control panel is tight.
▪ Hose routing from the fuel tank to the engine is
Note:
The installation and major repair work shall be carried out only by specifically
trained person.
open.
be closed when starting a cold engine.
correct. For proper operation, the hose must run
through the bushing in the lifting bracket. Refer to
the Parts Book for illustration.
GEEL 3, GEEL 5, GEEL 7
en
GEEL
31