Descargar Imprimir esta página

Veto A95 Manual página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
1. GenerAl
• submersible liquid level waterproof switch with maximum operating depth of 100 mt.
• designed to control the level of water, in particular sewage, waste water with suspended
solids and turbulent water.
• to operate a pump, two controls are required: one for the minimum and one for the
maximum level.
• moplen outer casing, blow moulded in a single piece.
• electrical switch 10A 250v with multiple self-cleaning contacts, not suitable for direct
connection to the pump.
cable
cable
type
lenght
A95A
Pvc
3 m
A95As1
Pvc
5 m
A95b
Pvc
10 m
A95bs1
Pvc
15 m
A95As2
neoprene
3 m
A95As3
neoprene
5 m
A95bs4
neoprene
10 m
A95bs5
neoprene
15 m
A95bs6
neoprene
20 m
A95bs7
neoprene
25 m
2. homoloGAtion And stAndArds
complies with en 60730-1, 60730-2-16. conformity with tüv.
3. oPerAtion
counterweiGht AssemblAGe
1. pull out the
stopping cone
2. insert the
electric cable
in the stopping
cone
4
sPdt
maximum
contact
immersion
rating
pressure
10(4)A 250vca
10 bar
10(4)A 250vca
10 bar
10(4)A 250vca
10 bar
10(4)A 250vca
10 bar
10(4)A 250vca
10 bar
10(4)A 250vca
10 bar
10(4)A 250vca
10 bar
10(4)A 250vca
10 bar
10(4)A 250vca
10 bar
10(4)A 250vca
10 bar
off-on
30°
differential
30°
on-off
3. insert the
electric cable in the
counterweight
e n G l i s h
maximum
Protection
temperature
degree
of the liquid
60 °c
iP68
60 °c
iP68
60 °c
iP68
60 °c
iP68
45 °c
iP68
45 °c
iP68
45 °c
iP68
45 °c
iP68
45 °c
iP68
45 °c
iP68
max level
counterweight
minimum level
Ø 77
4-5 mm
min.