Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
SLT966-EM SLT967-EM
EXTERNAL MOTOR
BUILT-IN INSTALLATION
The product SLT966 SLT967 EXTERNAL MO-
TOR version can be installed by following the
same instruction of SLT966 SLT967 BUILT-IN
DUCTING (as described on the previous page).
After the installation of the hood, follow the
instruction described in the remote motor to
complete the installation.
The cable of the remote motor must be con-
nected to the specific terminal block positio-
ned in the as shown in figure 7.
WORKING
RC001
R
C
ADIO
ONTROL
Radio control used for the remote operation
of ducted cooker hoods.

TECHNICAL DATA

- Alkaline battery powered: 12 V mod. 23 A
- Operating frequency: 433.92 Mhz
- Combinations: 32.768
- Max. consumption: 25 mA
- Operating temperature: -20 ÷ + 55 °C
- Dimensions: 120 x 45 x 15 mm.
OPERATING DESCRIPTION
The transmitter is equipped with 5 buttons
for cooker hood management, as specified
below:
: Light ON/OFF command.
: Motor ON (speed level 1) / OFF command.
: Reduce speed.
: Increase speed.
: 10-minute timer.
The set suction speed is indicated by the LED
in the suction perimeter channel.
To each color generated by the LED, it cor-
responds a specific speed, as shown below:
First speed WHITE
Second speed BLUE
Third speed DARK BLUE
Fourth speed RED
DIMMABLE LIGHTS FUNCTION
This function provides for lights dimmability,
ranging from 20% to 100% , by continuously
pressing the light key on the remote control.
Functions are the following:
- Hood light off shortly press the key light
on at 100%.
- Light on at 100% shortly press the key light
off.
- Light on at 100% continously press the key
brightness reduction.
- Releasing the key during reduction or in-
crease light keeps the luminous intensity re-
ached.
- Light on dimmed continously press the key
brightness is inverted if compared to the pre-
vious function.
INITIAL OPERATING CONDITION
The manufacturer supplies the radio control
unit ready to be used with codes preset in the
Factory.
OPERATION MODE
Standard configuration:
Standard configuration requires all "cooker
hoods – radio control - system" to be pro-
vided with the same transmission code. In
the event two cooker hoods – radio control
system are installed in the same room or ne-
arby, each system may affect the operation of
the another. Therefore, the code of one radio
control system must be changed.
Generatiing a new transmiissiion code:
The radio control system is provided with
preset codes. Should new codes be requi-
red, proceed as follows: Press simultaneously
buttons:
14

Publicidad

Tabla de contenido
loading

Productos relacionados para Energy SLT966

Este manual también es adecuado para:

Slt967

Tabla de contenido