BREAK-IN OFTHEPUMP
thetank.
1. Make sure thepower i sconnected atthepower panel.
2. Check t heoillevel i nthepump (see "Checking theOil"inthe
maintenance
section).
3. Open thepetcock (see C).
__
Escaping air and moisture
can
propel debris that may cause eye injury. Wear safety
goggles
when opening petcock.
4,
Turn ON the main power disconnect switch. Turn the
pressure switch to the AUTO position (see B). The motor
should start. Allow the compressor to run for 30 minutes, to
break in the internal parts.
NOTE:
After about 30 minutes, if the unit does not operate
properly, SHUT DOWN IMMEDIATELY,
and contact a
Sears or other qualified service center. DO NOT return
the unit to the store where it was purchased.
5.
Shut OFF the main power disconnect.
Close the petcock
(see D). Connect your air hose(s) to the tank outlet(s).
NOTE:
As compressed
air is used, the pressure switch will
restart the motor automatically to supply more
compressed
air to the tank.
DAILY
START-UP
1,
2,
3.
4.
Check the oil level in the pump (see "Checking the Oil" in the
maintenance section).
Make sure the main power disconnect switch is shut OFF.
Close the tank petcock (see D).
Turn ON the main power disconnect switch. Turn the
pressure switch to the AUTO position (see B). The pump wilt
start filling the tank with air. When the air pressure in the
tank reaches the level preset at the factory, the pressure
switch will turn off the electric motor. As air is used and the
pressure level in the tank drops, the pressure switch wilt start
the motor and the pump wilt begin refilling the tank.
__
High temperatures
are generated
by the pump. To prevent burns or other injuries, DO
NOT touch the pump or transfer
tube while the pump
is running.
Allow it to cool before handling
or
servicing.
Keep children away from the compressor
at all times.
NOTE:
If the unit does not operate properly, SHUT DOWN
IMMEDIATELY,
and contact a Sears or other qualified
service center.
SHUTDOWN
1.
Turn the pressure switch to the OFF position (see A).
2.
Shut OFF the main power disconnect switch.
3.
Reduce pressure in the tank through the outlet hose. You
can also pull the tank safety valve ring (see E) and keep it
open to relieve pressure in the tank.
__
Escaping air and moisture
can
propel debris that may cause eye injury. Wear safety
goggles
when opening petcock.
OFF (A)
(B) AUTO
/
i
',
:
C OP!'
4.
Open the petcock (see C) to allow moisture to drain from
8
200-2794