12m Wireless Outdoor Detector
EN50131-2-4:2008
EN50131-1:2006+A1:2009
Security Grade (SG)2
Environmental Class(EC)IV
E N G L I S H
Diagram References
1
Installation
Ensure that t he detector is installed away from reflected sunlight and large
objects.
2
Switches
ON position
OFF position
1
LEDs on
LEDs off
2
Buzzer on
Buzzer off
3
Top PIR high sensitivity
Top PIR low sensitivity
4
Bottom PIR high sensitivity
Bottom PIR low sensitivity
If you disable the detector's LEDs, you can remotely enable them in walk tests.
Microwave range and angle of detection
3
Use the highlighted dials to change the microwave range and angle
of detection.
4
LEDs
Four LEDs show the status of the detector.
5
Lens inserts
Use lens inserts to control the coverage area.
6
Registration procedure
After powering up and after registration,there is a 10 minute timer that allows
a walk test of the PIR and microwave sensors.You can set up the sensitivity and
microwave range without using the control panel to perform a walk test.After
10 minutes,the detector enters sleep mode. Please register the device within
90 seconds after it being powered on.
Register Locally
1.Make the security control panel enter the registration mode.
2. Register the detector: Hold the registration key until the three LEDs flash
alternately. The green LED will flash 8 times if the registration is finished.
3. Communication Test: Release the TEMPER spring to trigger the alarm.
Note: The distance between the security control panel and the detector should
be less than 50 cm.
Initialize the Detector
1. Remove the battery to power the detector off.
2. 5s later, hold the registration key and reinstall the battery to power the
detector on at the same time to make the three LEDs start flashing alternately.
Release the registration key while the three LEDs flash once together.
7
Signal strength test
Enter the signal checking mode by operating on the control panel
Indicator turns green:Strong Signal.
Indicator turns red:Weak Signal.
8
Bracket tamper signal input
Technical Specification
Detectors Technical Characteristics
Detection Range
12m
Detection Angle
90°
Detection Zones
2x22 zones
Detection Speed
0.25–2.5 m/s
Mounting Height
1-1.5 m
Two-way Wireless Technology
Yes
Blue Wave Technology
Yes
Dual Element Pyroelectric Sensor
Yes
Tamper Protection
Front, rear, and bracket tamper signal input
Intergrated Walk Test Buzzer
Yes
Separated LED Indication:
Top: Microwave, PIR 1 and alarm
Orange(Microwave),Blue(Alarm),Green(PIR)
Bottom: PIR 2
Signal Strength Indicators (SSI)
Yes
3 Microwave Frequencies to Avoid Interference
Yes
Digital Independent Floating Threshold(IFT) Technology
Yes
Plastic Housing
3mm polycarbonate
Animal Immunity
Up to 24kg
Optics
Dual-vision sealed optics
Adjustable Sensitivity
High or low range
Lens
UV compensated
Detection Method
Tri-Signal Detection Logic
Sensor
2 low noise dual element passive infrared sensors and a microwave doppler unit
Environmental and Operating Features
Weatherproof
IP55 rated
Certified Operating Temperature
-25℃ to +60℃(Certified)
Physical Dimensions(H x W x D)
118mm x 77mm x 84mm
Weight
0.3kg
Electrical & battery
Battery Type
2x3V 4700mAh Lithium battery packs
Battery Life
Up to 3 years
Battery Capacity
4700mAh
Accessories
Rotatable Wall Mounted
Yes – additional wall and fixed brackets available separately
Fixed Wall Mounted
Yes – additional wall and fixed brackets available separately
Ceiling Mounted
Yes – additional wall and fixed brackets available separately
Battery
Yes – additional battery available separately
Battery Information
The batteries supplied with this product have been chosen to provide long service life whilst, for safety
reasons, having limited output current.The battery leads must be connected for operation. When disposing
of the product, remove the batteries and disposed of separately in accordance with the local regulations.
1
2
4
3
5

Publicidad

loading

Resumen de contenidos para HIKVISION DS-PD2-T12P-WEL

  • Página 1 DS-PD2-T12P-WEL DS-PD2-T12P-WEL/WEL1 12m Wireless Outdoor Detector EN50131-2-4:2008 EN50131-1:2006+A1:2009 Security Grade (SG)2 Environmental Class(EC)IV E N G L I S H Diagram References Installation Ensure that t he detector is installed away from reflected sunlight and large objects. Switches ON position...
  • Página 2 Any and all information, including, among others, wordings, pictures, graphs are the properties of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinafter referred to be “Hikvision”). This user manual (hereinafter referred to be For electrical products sold within the European Community.
  • Página 3 F R A N Ç A I S P O R T U G U Ê S I T A L I A N O E S P A Ñ O L Références du schéma Referências do diagrama Riferimento schemi Referencias del diagrama Installation Instalação...
  • Página 4 Р У С С К И Й D e u t s c h P o l s k i Ссылки на рисунки Schaubilder Opis diagramu Установка Installation Instalacja Удостоверьтесь, что датчик устанавливается вдали от отраженных солнечных лучей и Vergewissern Sie sich, dass der Melder nicht in der Nähe von reflektiertem Sonnenlicht und großen Objekten Upewnij się, że czujnik jest zainstalowany z dala od odbitego światła słonecznego i dużych obiektów.

Este manual también es adecuado para:

Ds-pd2-t12p-wel1