DS-PD2-T12P-WEL
DS-PD2-T12P-WEL/WEL1
12m Wireless Outdoor Detector
E N G L I S H
Diagram References
1
Installation
Ensure that the detector is installed away from reflected sunlight and large objects.
2
Switches
ON position
OFF position
1
LEDs on
LEDs off
2
Buzzer on
Buzzer off
3
Top PIR high sensitivity
Top PIR low sensitivity
4
Bottom PIR high sensitivity
Bottom PIR low sensitivity
If you disable the detector's LEDs, you can remotely enable them in walk tests.
3
Microwave range and angle of detection
Use the highlighted dials to change the microwave range and angle of detection.
4
LEDs
Four LEDs show the status of the detector.
5
Lens inserts
Use lens inserts to control the coverage area.
6
Registration procedure
After powering up and after registration,there is a 10 minute timer that allows
a walk test of the PIR and microwave sensors.You can set up the sensitivity and
microwave range without using the control panel to perform a walk test.After
10 minutes,the detector enters sleep mode. Please register the device within
90 seconds after it being powered on.
Register Locally
1. Make the security control panel enter the registration mode.
2. Register the detector: Hold the registration key until the three LEDs flash
alternately. The green LED will flash 8 times if the registration is finished.
3. Communication Test: Release the TEMPER spring to trigger the alarm.
Note: The distance between the security control panel and the detector should
be less than 50 cm.
Initialize the Detector
1. Remove the battery to power the detector off.
2. 5s later, hold the registration key and reinstall the battery to power the
detector on at the same time to make the three LEDs start flashing alternately.
Release the registration key while the three LEDs flash once together.
Register Via APP
1. Log in to the APP Store and input "Hik-Connect" to search the mobile client.
Download and install Hik-Connect to your phone.
2. After installing, tap
to run the client.
3. Power on the security control panel.
4. Log in the Hik-Connect and tap the icon "+" at the upper-right coner of the
Hik-Connect page to add the security control panel. You can scan the QR code
on the device rear panel or on the package box, or on the package box, or input
the device serial No. manually to add the device when the device is in the
registration mode.
5. After adding the security control panel, tap the arming status icon on the
right of the security control panel's name to enter the Partition page.
6. Tap the "+" icon on Partition page to add the peripherals.
7
Signal strength test
Enter the signal checking mode by operating on the control panel
Indicator turns green:Strong Signal.
Indicator turns red:Weak Signal.
8
Bracket tamper signal input
Technical Specification
Detectors Technical Characteristics
Detection Range
12m
Detection Angle
90°
Detection Zones
2x22 zones
Detection Speed
0.25–2.5m/s
Mounting Height
1-1.5m
Two-way Wireless Technology
Yes
Blue Wave Technology
Yes
Dual Element Pyroelectric Sensor
Yes
Tamper Protection
Front, rear, and bracket tamper signal input
Yes
Intergrated Walk Test Buzzer
Top: Microwave, PIR 1 and alarm
Separated LED Indication:
Orange(Microwave),Blue(Alarm),Green(PIR)
Bottom: PIR 2
Signal Strength Indicators (SSI)
Yes
3 Microwave Frequencies to Avoid Interference
Yes
Digital Independent Floating Threshold(IFT) Technology
Yes
Plastic Housing
3mm polycarbonate
Up to 24kg
Animal Immunity
Optics
Dual-vision sealed optics
High or low range
Adjustable Sensitivity
Lens
UV compensated
Detection Method
Tri-Signal Detection Logic
Sensor
2 low noise dual element passive infrared sensors and a microwave doppler unit
Environmental and Operating Features
Weatherproof
IP55 rated
Certified Operating Temperature
-25℃ to +60℃(Certified)
118mm x 77mm x 84mm
Physical Dimensions(H x W x D)
0.3kg
Weight
Electrical & battery
Battery Type
2x3V 4700mAh Lithium battery packs
Battery Life
Up to 3 years
Battery Capacity
4700mAh
Accessories
Rotatable Wall Mounted
Yes – additional wall and fixed brackets available separately
Fixed Wall Mounted
Yes – additional wall and fixed brackets available separately
Battery Information
Ceiling Mounted
Yes – additional wall and fixed brackets available separately
Battery
Yes – additional battery available separately
Battery Information
The batteries supplied with this product have been chosen to provide long service life whilst, for safety
reasons, having limited output current.The battery leads must be connected for operation. When disposing
of the product, remove the batteries and disposed of separately in accordance with the local regulations.
1
UD15579B
2
4
3
5