Descargar Imprimir esta página

MUNDO CLIMA MUPR-09-H6 Manual De Instalación Y Usuario página 88

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

WARNING
BEFORE PERFORMING ANY ELECTRICAL
OR WIRING WORK, TURN OFF THE MAIN
POWER TO THE SYSTEM.
1. Prepare the cable for connection:
USE THE RIGHT CABLE
Cable Types
• Power Cable: H07RN-F
• Signal Cable: H07RN-F
Model
MUPR-09-H6
MUPR-12-H6
MUPR-18-H6
MUPR-24-H6
Outdoor unit terminals
2(N)
1(L)
W
S L
to Indoor Unit
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal
cable, fuse, and switch needed is determined
by the maximum current of the unit. The
maximum current is indicated on the nameplate
located on the side panel of the unit. Refer to
this nameplate to choose the right cable, fuse,
or switch.
a. Using wire strippers, strip the rubber
jacket from both ends of cable to reveal
about 15cm (6in) of the wires inside.
b. Strip the insulation from the ends of the
wires.
c. Using a wire crimper, crimp u-lugs on the
ends of the wires.
Power Cable (mm²)
2 x 2.5 + T
2 x 2.5 + T
2 x 2.5 + T
2 x 4 + T
N
Power Supply
88
PA Y ATTENTION TO LIVE WIRE
While crimping wires, make sure you clearly
distinguish the Live ("L") Wire from other wires.
WARNING
ALL WIRING MUST PERFORMED STRICTLY
IN ACCORDANCE WITH THE WIRING
DIRGRAM LOCATED INSIDE THE OUTDOOR
UNIT S WIRE COVER.
'
2. Unscrew the electrical wiring cover and
remove it.
3. Unscrew the cable clamp below the terminal
block and place it to the side.
4. Match the wire colors/labels with the labels on
the terminal block, and firmly screw the u-lug
of each wire to its corresponding terminal.
5. After checking to make sure every connection
is secure, loop the wires around to prevent
rain water from flowing into the terminal.
6. Using the cable clamp, fasten the cable to the
unit. Screw the cable clamp down tightly.
7. Insulate unused wires with PVC electrical tape.
Arrange them so that they do not touch any
electrical or metal parts.
8. Replace the wire cover on the side of the unit,
and screw it in place.
Cover
Outdoor Unit Wiring Diagram
is located on the inside of the
wire cover on the outdoor unit.
Fig. 4.6

Publicidad

loading

Este manual también es adecuado para: