Rust protection and internal cleaning
Water in the compressed air, dust and wear particles cause rust
and sticking of vanes, valves etc. An air filter should be installed
close to the machine (see 'Air quality'). Before longer standstills,
flush with oil (some drops) into the air inlet, run the machine for
5-10 seconds when absorbing the oil in a cloth.
Service instructions
Overhaul and preventive maintenance is recommended at regular
intervals once per year or after maximum 250.000 tightenings de-
pending on which occurs sooner. More frequent overhaul may be
needed, specially changing oil in the pulse unit, if used at high
torque and long tightening times. If the machine is not working
properly, it should immediately be taken away for inspection.
The strainer at the air inlet and the exhaust silencer should be
cleaned frequently or replaced in order to prevent clogging, which
decreases the capacity.
At the overhauls, all parts should be cleaned accurately and de-
fective or worn parts (i.e. O-rings, vanes) should be replaced.
A
All o-rings should be greased before assembling; especially
important are the o-rings in the pulse unit.
Disassembling /assembling
It is important that the machines threaded connections are tightened
properly; i.e. in accordance with the specifications on the exploded
views.
Cleaning
Clean all parts, not electrical, thoroughly in white spirit or similar
cleaning agent. To prevent clogging and decreased power, it could
be necessary to clean the strainer (if used) and the exhaust filter
between the overhauls.
Inspection
After the cleaning, inspect all parts. Damaged and worn parts
should be replaced.
Lubrication
Lubricate specially gears, valve and clutch with grease containing
molybdenum disulphide (e.g. Molykote BR2 Plus). Lubricate o-
rings and threaded connections with grease before assembling.
Grease Guide
Brand
General purpose
Bearings
BP
Energrease LS-EP2
Castrol
Spheerol EP L2
Esso
Beacon EP2
Q8
Rembrandt EP2
Mobil
Mobilegrease XHP
222
Shell
Alvania EP2
Texaco
Multifak EP2
Molycote
Lubricating
Engineers
Spare parts
Parts without ordering number are for technical reasons not de-
livered separately.
The use of other than genuine CP replacement parts may result
in decreased tool performance and increased maintenance and
may, at the company option, invalidate all warranties.
Motor
Air Lubrication
shaft
Energol E46
Arox EP46
Chopin 46
Almo oil 525
Tonna R32
Aries 32
BR2 Plus
Almagard-
3752
EN
Technical data
Noise and vibration emission
Noise (according to EN ISO 15744)
Measured sound pressure level
Determined sound power level
Spread in method and production
Vibration (according to ISO 8662-7)
Measured vibration value
Spread in method and production
Declaration of noise and vibration emission
These declared values were obtained by laboratory type testing in
compliance with the stated standards and are not adequate for use
in risk assessments. Values measured in individual work places
may be higher than the declared values. The actual exposure values
and risk of harm experienced by an individual user are unique and
depend upon the way the user works, the workpiece and the
workstation design, as well as upon the exposure time and the
physical condition of the user.
We, Desoutter, can not be held liable for the consequences of
using the declared values, instead of values reflecting the actual
exposure, in an individual risk assessment in a work place situation
over which we have no control.
dB(A)
82
Noi s espread-vol u me
2
m/s
8.6