Descargar Imprimir esta página

Cardin BLA230S Manual Del Usuario página 29

Automatizacion para cancillas batientes

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Terminal board connections
1
Outer conductor for radio receiver antenna.
2
Inner conductor for radio receiver antenna (if an external antenna is fitted use
a coaxial type cable RG58 with an impedance of 50Ω)
3
CMN per CH2
CH2 Potential free N.O. contact requires separate power supply Vmax = 30
4-5
Vac/dc: Imax = 1A
6
CMN common for all inputs and outputs
7
24 Vdc controlled output, powering external loads
LS output for an indicator light 24 Vac 3W
8
9
CMN common for all inputs and outputs
10
ELS electric lock output 12 Vac – 15 W
CMN common for all inputs and outputs
11
12
EMRG1 (NO contact) emergency manoeuvring button input 1
13
EMRG2 (NO contact) emergency manoeuvring button input 2
14
CMN common for all inputs and outputs
24 Vdc output, powering external loads
15
16
CMN common for all inputs and outputs
17
FCC1 (N.C.) gate 1 closing travel limit input
FCA1 (N.C.) gate 1 opening travel limit input
18
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
19
FCC2 (N.C.) gate 2 closing travel limit input
20
FCA2 (N.C.) gate 2 opening travel limit input
21
CMN common for all inputs and outputs
TAL (NO contact) limited opening button input
22
23
TA (NO contact) opening button input
24
TC (NO contact) closing button input
TD (NO contact) dynamic button input
25
26
CMN common for all inputs and outputs
27
TB (N.C./8.2 kΩ) stop button input (The opening of this contact interrupts the
cycle until a new movement command is given)
CSP (N.C./8.2 kΩ) safety edge input. Opening this contact will provoke a travel
28
direction inversion during the closing stage and during the opening stage
29
FTCS (N.C./8.2 kΩ) The opening of this contact will block all movement, until
the obstruction has been removed and the pause time has elapsed, due to
the safety device cutting in, the door will then continue moving in the closing
direction (only with automatic reclosing enabled)
L2
L5
L3
L4
ON
R1
1
2
3
NC NC NC NC
14 15
16 17
18
19
20
CS1484A
DC0562
D1
Six-segment LED display
DS1
Selection dip-switch
F1
1A fuse (delayed 24V circuit protection)
F2
4A fuse (delayed 230V circuit protection) )
rawing number :
DC0562
(1)
( (1)
(2)
(2)
L1
L6
L8
D1
L7
L9
P1
PROG
J1
POS. 1
POS. 2
NO NO
NO
4
5
6
7
8
9
10
11
12
13
NO
OUT CH2
NO
NO
NO
NO
NO
NC
NC
NC
NC
21
22
23
24
25
26
27
28
29 30 31
Description :
Programmatore a microcontrollore per 1-2 motori
30
31
32-33
34-35
36-37-38 Motor M2 in output Opening- Closing- Common
39-40-41 Motor M1 in output Opening- Closing- Common
42-43
44
45
46
Note
The total of the 2 external device outputs must not exceed 10 W.
(1)
Note
The selection of the type of contact (N.C./8.2 kΩ) is carried out using parameter
(2)
"SC" on the six-figure display.
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently
the security device test must also be deactivated (FTCI , FTCS - Dip 9 and
Dip 10 "OFF").
If you want to activate the FTCI, FTCS test both the transmission and receiver
parts of the security devices must be connected to the binding post marked
"CTRL 24 Vdc". If the test is active there will be a 1 second delay between
the command transmission and movement of the gate/s.
Switch on the power and make sure that the indicator LEDs are in the fol-
lowing condition.
- L1 Power on
- L2 Indicator for the blocking button "TB"
- L3 Indicator for the inverting photoelectric cells "FTCI"
- L4 Indicator for the stop photoelectric cells "FTCS"
- L5 Indicator for the safety edge "CSP"
- L6 Indicator for the opening button "TA"
(2)
- L7 Indicator for the opening button "TC"
- L8 Indicator for the limited opening button "TAL"
- L9 Indicator for the sequential command "TD/CH1"
F1
F3
32 33
34
35
36
37
38
39
40
41
C.
C.
M1
M2
F3
J1
P1
R1
9
FTCI (N.C./8.2 kΩ) safety and control devices in input (photocells invert
the travel direction when an obstruction is detected). Opening this contact
will provoke a travel direction inversion during closure due to the cutting
in of the safety device
(2)
CMN common for all inputs and outputs
230Vac 40W courtesy light output
230Vac 40W warning light output (intermittent or continuous activation)
Electronic programmer power supply 230Vac 50/60Hz
Electronic programmer earth wire 230Vac 50/60Hz
Earth connection
Earth connection
Note
Check that the activation of the safety
(3)
devices switches the corresponding LEDs off.
If the green power on LED "L1" doesn't light
up check the condition of the fuses and the
power cable connection.
If one or more of the safety LEDs do not
light up check the contacts of the relative
security devices and check that the unused
safety device contacts have been bridged.
F2
42
43
44
45
46
L
N
1,6A fuse (delayed electric lock protection)
EMRG selection jumper (On/Off)
Programming button (PROG)
Standard radio receiver interface
ON
ON
(3)
ON
(3)
ON
(3)
ON
(3)
OFF
OFF
OFF
OFF

Publicidad

loading

Este manual también es adecuado para:

Bla serieBla230l