Important: Safety Instructions
This manual provides you with important information about the Vacuum Regulators and should be read carefully to ensure
the safe and proper use of this product.
Read and understand all the safety and operating instructions contained in this booklet.
If you do not understand these instructions, or have any questions, contact your supervisor, dealer or the manufacturer
before attempting to use the apparatus.
Intended Use
Amvex Vacuum Regulators are intended to regulate a supplied vacuum pressure to the users desired vacuum level. A
gauge shows the value of the regulated vacuum, which is adjustable via a regulating knob.
WARNING
Indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury
ATTENTION
Indicates a potentially hazardous situation, which if not avoided, could result in minor or moderate injury
CAUTION
Indicates a potentially hazardous situation, which if not avoided, could result in damage to the device or other property
Complies with the requirements of Directive 93/42/EEC
Manufacturer's authorized representative in the European Union
Caution
Caution: Federal (USA) Law restricts this device to sale by or on the order of a licensed healthcare provider.
The stork symbol indicates low pressure vacuum gauge commonly used for pediatric and neonatal applications
Analog gauges include color coding along the graduation marks as follows:
Analog Gauge Color
Green
GAUGE
COLORS
Yellow
Orange
Red
Receiving Inspection
Remove product from package and inspect for damage. If product is damaged, DO NOT USE and contact your
dealer or equipment provider.
ATTENTION:
It is very important to allow product to remain in original packaging for 12-24 hours to
acclimate to room temperature before use.
User Responsibility
WARNING:
The procedures described in this service manual should be performed by trained and
authorized personnel only. Maintenance should only be undertaken by competent individuals
who have a general knowledge of and experience with devices of this nature. Read
completely through each step in every procedure before starting this procedure; any
exceptions may result in a failure to properly and safely complete the attempted procedure.
No repairs should ever be undertaken or attempted by anyone not having such qualifications.
Genuine Amvex replacement parts must be used for all repairs. This product performs as
explained in this manual as long as the assembly, use, repair and maintenance are properly
followed according to our instructions. Elastomers and other components may become worn
2
Amvex Vacuum Regulator Operating & Maintenance Manual
Manufacturer
Serial Number
160 mmHg Gauge
0 – 80 mmHg Graduations
80 – 120 mmHg Graduations
120 – 160 mmHg Graduations
N/A
VR-MANUAL (Rev. 1) 07/2023
Product Disposal Instructions
Catalog Number (Device Identifier)
Consult operating manual
300 mmHg Gauge
0 – 80 mmHg Graduations
80 – 120 mmHg Graduations
120 – 200 mmHg Graduations
200 mmHg – Full Graduations