TROUBLESHOOTING GUIDE
EN
PROBLEM
No Water When Activated
Red LED stays on or fl ashes in
electronic eye (if not AC powered)
Very Low Flow or Slow Dribble
False Triggering
(Unit goes on by itself )
Continues to Run
(Even after power to faucet has been
reconnected)
POSSIBLE CAUSE/SOLUTION
1. Replace batteries.
1. Check supply stop(s); open if closed.
2. Debris in supply hose fi lter washers in
1/2" NPSM swivel end; remove, clean
and reinstall.
3. Debris in aerator or spray head;
remove, clean, and reinstall.
1. Check surroundings for factors that
can contribute to the false triggering;
for example, bright lights, highly
refl ective surfaces, sunlight, etc.
2. Range too long; decrease sensor
range.
1. Debris in solenoid valve, won't close
properly. Contact factory.
32