Avoid strong swinging movements
on the vehicle
1.5
Technical data
Type
Max. Load capacity
Time for lifting (2000 kg)
Time for lowering (2000 kg)
Drive
Required compressed air supply
Working pressure
2
Recommended hydraulic oil
Oil quantity
Permissible sound value
Permissible operating temperatures
Weight
Warning
The factory-set working pressure is adjusted to the maximum nominal load. The pressure
2
relief valve must not be manipulated.
Changing the setting can lead to serious damage.
Note
If the specified nominal load cannot be raised, please contact our service team.
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved
If there is a danger of a vehicle
falling, leave the danger area
immediately.
2500 kg
Approx. 20 s
Approx. 20 s
Air-hydraulic pedal pump
3 - 10 bar
Max. 700 bar
Summer (10° to 45°): H-LPD 32
Winter (below 10°): HVLP-D 22
Approx. 0,75 l
≤ 70 dB
-10 - +40°C
150 kg
Release date: 16.11.2023 / Product manufacturer ATH-Heinl GmbH & Co. KG
It is forbidden to ride on mobile lifting
platforms.
45