TYPICAL
iNSTALLATiON
MOUNTING
(New Frame
Construction)
10" ROUND DUCT
[
8" TO 10" ROUND
TRANSITION
1½" FRAMING
10" ROUND
DUCT
/
Blower
factory-
shipped
in straight
through
discharge
position.
CEILING JOIST
(16" centers
shown)
Mounting brackets factory-
shipped in position for
½" ceiling material.
MOUNTING SCREW
Factory-shipped
unit
installed
in new
construction.
MOU NTING (Existing
Frame Construction)
8" TO 10" ROUND
TRANSITION
10" ROUND DUCT
(OUTLET)
CEILING JOIST
(16" centers
shown)
MOUNTING
BRACKETS
(Attached to
opposite sides
of housing &
upside-down)
10" ROUND
DUCT
(INTAKE)
2 X 4 FRAMING
(wide side down)
Blower
Jbctory-shipped
in straight-through
discharge
position.
iMPORTANT: Remove shipping
tape from damper
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork. Use
duct tape to make ductwork connections secure and air-tight.
Remove
shipping
ring from blower
inlet
Remove the shipping ring from the blower inlet before operating
the ventilator.
Page 2
TYPICAL
INSTALLATION
MOUNTING
USING HANGER
KIT (included)
HANGER
KIT BOLT
& WASHER
EXTENSION
SPRING
HANGER
10" ROUND
"_ _
DUCT (INTAKE)
KIT CHAIN
_ _i
HANGER KIT
EYE-BOLT
8"TO 10"
ROUND
TRANSITION
HANGER
KIT NUT &
WASHER
BRACKET
", _
GRILLE NUT
_
(Install into
_
square holes in
10"
(OUTLET)
DUCT
ROUND
<,
,,_
housing)
/ "4...
_
ACCESS
ACCESS PANEL _
i-'--
PANEL SCREW
Blower
factolT-shipped
in straight-through
discharge
position.
DUCTING
(Horizontal
blower
discharge)
ROUND DUCT
/
ROUND
ELBOW
WALL
CAP
Two ways to connect ductwork
to a Jbctory-shipped
unit.

Publicidad