OLIMPIA
READ THE FOLLOWING WARNINGS BEFORE PROCEEDING TO INSTALL OR DO MAINTENANCE WORK ON THE
WARNING: PRODUCT INTENDED FOR PROFESSIONAL USE, BY SKILLED PEOPLE.
WARNING: MAINTENANCE WORK ON THE PUMP MUST ONLY BE CARRIED OUT BY AUTHORISED, TRAINED
Install the pump in a place where the temperature does not exceed 40°C and the relative humidity is below 90%.
This pump has a protection level of IP65 and so can be installed outdoors. This pump must never be immersed in
liquid. To prevent overheating do not install the pump in direct sunlight.
Check that the power supply voltage fed to the plant is as indicated in the label on the pump.
I
WARNING: BEFORE DOING ANY WORK ON THE PUMP, ALWAYS FIRST DISCONNECT THE POWER
SUPPLY CABLE.
When handling the pump after it has been used to dose chemical products, remember to use protective clothing
and gloves and to provide suitable protection for your eyes.
If you are dosing using pressurised piping, before starting the pump always check that the pressure in the plant
does not exceed the maximum working pressure shown on the dosage pump label.
I
WARNING: BEFORE DOING ANY WORK ON THE PUMP, ALWAYS FIRST DISCONNECT THE POWER
SUPPLY CABLE.
Check the pump's main characteristics indicated on the nameplate.
Your pump is one of the family of pumps listed in the table below:
Pressure
Model
bar
0502
2
0207
7
0505
5
Fig.7 Overall dimensions of pump
Cod. EM00136047_rev. 2.0
PUMP.
PERSONNEL
TECHNICAL CHARACTERISTICS
Flow Rate
cc / stroke
L/h
5
0.75
2
0.33
5
0.60
OVERALL DIMENSIONS AND DRILLING TEMPLATE
DosingPump.ir
Connections
(mm)
Strokes / min
IN / OUT
110
4 / 6
100
4 / 6
140
4 / 6
Fig.8 Bracket drilling template
Weight
Kg
1,4
1,4