Electrical Rough-in
2
Locate the multi-conductor cable (supplied with steam generator). Carefully route this interface cable from the
steam generator to the 8CN-600S, 8CH-600S or 8CB-600S Series Digital Interface located inside the steam
room (see Figure 1). Route this interface cable through a 3/4" conduit to protect the cable from damage and to
facilitate replacement if necessary.
3
Interface and Cable Installation
1. Locate the previously installed interface cable and black plastic strain relief clamp. Locate the knockout on
the steam generator for the interface cable (see Figure 2).
2. Place strain relief clamp around cable approximately seven inches from the end and insert into the hole.
3. Remove the protective cap from the multi-conductor cable plug. Connect the cable to the modular jack.
4. Close and secure the steam generator cover.
5. Locate the modular jack at the female coupler, on the back of the 8CH-600S, 8CB-600S or 8CN-600S
Series Digital Interface. Remove protective cap from cable and plug into jack. Confirm that the orientation
of the plug properly aligns with the jack. A snap will indicate the plug is installed correctly (see Figure 3).
6. Peel adhesive liner from the back of the interface. Apply silicone (supplied) around the back edge of the
interface to form a watertight seal (see Figure 3).
7. Apply the interface to the wall. Press firmly and hold for a few seconds. Wipe any excess silicone from
around the interface.
IMPORTANT: The 8CN-600S, 8CH-600S and 8CB-600S interfaces have built in temperature sensors and
therefore MUST be installed inside the steam room.
IMPORTANT: The adhesive on the back of the 8CH-600S, 8CB-600S & 8CN-600S Series Digital Interfaces will
NOT seal this interface. It is the responsibility of the installer to seal this interface to the wall with the supplied
silicone. Water damage to the interface based on improper installation is not covered by the warranty.
IMPORTANT: 8CH-600S, 8CB-600S & 8CN-600S Series Digital Interface cables MUST plug directly into the
steam generator. Do NOT plug this interface into any of the optional spa options.
Steam temperature settings: 60ºF minimum to 125ºF maximum
Maximum Time setting: 60 Minutes
Figure 2 - Cable Installation on Generator
113040 Rev. C
WARNING
!
Test the interface for operation before
continuing on to the next step.