EXTRA POWER function
(for models featuring a user interface as represented in figure 3)
The product usually operates at its basic power level.
The EXTRA POWER function activates additional power to speed up the rate at which water is heated. To activa-
illuminated button (Ref. B), which will light up in yellow. To deactivate it, press the same button
te it, press the
again; the light will switch off.
SMALT POWER SYSTEM
The SMALT POWER SYSTEM, our own unique solution, is an electronic system to protect the tank against
corrosion, which helps the optimal longevity of your water heater tank even if in case of presence of extremely
aggressive water. The electronic circuit creates a potential difference between the tank and the titanium electro-
de, in order to ensure optimal protection of the tank and prevent corrosion.
The proper functioning of the protection system requires a permanent supply connection to 230V, even
in cases of arrest of function of heating water.
In order to obtain a proper functioning of the appliance, the manufacturer recommends every 3 years to
carry out routine maintenance, replacing in case it's needed the magnesium anode.
The electronic circuit, in addition to being connected to the mains at 230V, is also connected to the electrode of
titanium and protection to the tank to be protected.
The function of the protective device is marked by continuous green light
(Ref. C fig. 3 and 4), indicating the
presence of a sufficient voltage in the terminals of the circuit.
USEFUL INFORMATION (for the user)
Before any operation of cleaning the device make sure to turn off the product by bringing the external switch to
the OFF position. Do not use insecticides, solvents or aggressive detergents that may damage the painted parts
or plastic material.
If the water delivery is cold, have the following checked:
- that the device is connected to the power supply and the external switch is in the ON position.
- that at least led 40°C (ref. 1) is turned on (for models equipped with the user interface shown in Figures 3 and 4);
If there is presence of steam output from the taps:
Remove power from the electrical appliance and contact technical support.
If the hot water delivery is insufficient, have the following checked:
- the pressure of the water mains;
- eventual obstruction of the inlet and outlet pipes (deformation or sediment).
Water trickling from the pressure safety device
During the heating phase, some water may trickle from the tap. This is normal. To prevent the water trickling, a
suitable expansion vessel must be installed on the flow system. If the trickling continues even after the heating
phase, have the following checked:
- device calibration;
- the pressure of the water mains.
Caution: Never obstruct the appliance outlet!
IF THE PROBLEM PERSISTS,NEVER ATTEMPT TO REPAIR THE APPLIANCE YOURSELF - ALWAYS HAVE
THIS DONE BY A QUALIFIED TECHNICIAN.