Descargar Imprimir esta página

Danfoss ERC 211 Guia De Instalacion página 17

Ocultar thumbs Ver también para ERC 211:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
Parameter name - ERC 211
Others
Delay of outputs
at startup
DI1 configuration
oFF=not used,
Sdc=status display output,
doo=door alarm with resumption,
doA=door alarm without resumption,
SCH = main switch, nig=day/ night mode,
rFd=reference displacement,
EAL=external alarm,
dEF=defrost, Pud=pull-down,
Sc=condenser sensor
Serial address
Password
Sensor type selection
n5=NTC 5 K, n10=NTC 10 K,
Ptc=PTC, Pt1=Pt1000
Cooling/heating
rE=refrigeration (cooling)
Ht=heating
Display resolution
0.1=steps of 0.1 °C
0.5=steps of 0.5 °C,
1.0=steps of 1.0 °C
Relay 1 counter
(1 count=100 cycles of operation)
Predefined applications
Save settings as factory
WARNING: the earlier factory settings are
overwritten
Display at defrost
Air=actual air temperature, FrE=freezed
temperature, -d-="-d-" is displayed
Note: hidden parameters are greyed out
DKRCE.PI.RL0.F7.ML
Code
Min
Max
Unit
o--
o01
0
600
min
o02
oFF
Sc
o03
0
247
o05
no
999
o06
n5
Pt1
o07
rE
Ht
o15
0.1
1.0
o23
0
999
o61
AP0
AP5
o67
no
yES
o91
Air
-d-
Installation Guide | ERC 211
App. 0
App. 1
App. 2
App. 3
(Def.)
5
5
5
oFF
oFF
oFF
0
0
0
no
no
no
n10
n10
n10
rE
rE
rE
0.1
0.1
0.1
0
0
0
AP0
AP1
AP2
no
no
no
-d-
-
-d-
App. 4
App. 5
5
5
5
oFF
oFF
oFF
0
0
-
no
no
no
n10
n10
-
rE
Ht
rE
0.1
0.1
0.1
0
0
-
AP3
AP4
-
no
no
-
-d-
-
-d-
| 17

Publicidad

loading