Installation
(Cont.)
compressor in a dean, well ventilated
area
where the surrounding
air temperature
will not be more than 100°F.
A minimum
clearance
of 18 inches
between
the compressor
and a wall is
required
because objects could obstruct
air flow.
DO not locate the
[_CAUTION]
comp . ......
ir
inlet near steam, paint spray, sandblast
areas or any other source of
contamination.
This debris will damage
the motor.
ELECTRICAL INSTALLATION
I_WARNINGI
AIIwiringand
electrical
connections should be performed by a
qualified electrician. Installation must be
in accordance with local codes and
national electrical codes.
[,_CAUTION]
Never use an extension
cord with this product. Use
additional air hose instead
of an extension cord to
avoid power loss and permanent motor
damage. Use of an extension cord voids
the warranty.
GROUNDING
INSTRUCTIONS
1. This product is for use on a nominal
120 volt circuit and has a grounding
plug that looks like the plug illustrated
in Fig. 3. Make sure the product
is
connected to an outlet
having the
same configuration
as the plug. This
product
must be grounded,
tn the
event of an electrical short circuit,
grounding
reduces risk of electrical
shock by providing
an escape wire for
electric current. This product
is
equipped
with a cord having a
grounding
wire with an appropriate
grounding
plug. Plug must be plugged
into an outlet that is properly
installed
and grounded
in accordance with all
local codes and ordinances.
Groo:d_ng
_]
Grounded Outlet
Figure 3 - Grounding
Method
Improper use of
grounding plug can re.
suit in a possible risk of
electrical shock!
_
l_notusea
grounding
adapter
with this product!
2. If repair or replacement
of cord or plug
is necessary, do not connect grounding
wire to either fiat blade terminal.
The
wire with insulation having an external
surface that is green (with or without
yellow stripes) is the grounding
wire.
IAWARNINGI Never conner
green (or green and
yellow) wire to a live terminal.
3. Check with a qualified
electrician or
serviceman if grounding
instructions
are not completely
understood,
or if in
doubt as to whether
product
is
properly grounded.
Do not modify
plug provided;
if it will not fit outlet,
have proper outlet installed by a
qualified
electrician.
WIRING
1. Local electrical wiring codes differ from
area to area. Source wiring, plug and
protector must be rated for at least the
amperage and voltage indicated on
motor nameplate, and meet all electrical
codes for this minimum.
2. Use a slow blow fuse or a circuit
breaker.
Overheating, short
[ACAUTIONI
circuitingandfire
damage will result from inadequate
wiring, etc.
NOTE: 120 volt, 15 amp units can be
operated
on a 120 volt circuit under the
following
conditions:
a. No other electrical appliances or lights
are connected
to the same branch
circuit.
b. Voltage supply is normal.
c. Circuit isequipped
with a 15 amp
circuit breaker or a 15 amp slow blow
fuse.
3. If these conditions
cannot be met or if
nuisance tripping
of current
protection
device occurs, it may be
necessary to operate compressor from
a 120 volt, 20 amp circuit.
Operation
Pressure
Switch
- Auto/Off
Switch - In
the ON position,
the compressor
shuts
off automatically
when tank
pressure
reaches the maximum
preset pressure.
The compressor
will automatically
restart when it reaches the minimum
preset pressure, in the OFF position,
the compressor
will not operate.
This
switch should
be in the OFF position
when connecting
or disconnecting
the
power
cord from the electrical
outlet
or when changing
air tools.
Regulator
_The regulator
controls
the
amount
of air pressure released at the
hose outlet.
ASME
Safety
Valve
_This valve
automatically
releases air if the tank
pressure exceeds the preset maximum.
Safety
Valve
Tool
Storage
Regulator
Figure
4
Gauge of Cord
18
14
12
10
8
8
6
6
4
www.chpower.com