Descargar Imprimir esta página

Dimplex Optimyst Cassette 500 Manual De Instrucciones página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Information,
Heat Output
Nominal Heat Output
Minimum Heat Output
Maximum Continuous Heat Output
Auxiliary Electricity Consumption
In Standby Mode
No room temperature control
INSTALLATION INSTRUCTIONS
This section describes how to install and set up your fire.
BEFORE YOU START:
Ensure that all packing items are removed (read any warning labels carefully) and retain all packing for possible
future use.
Before connecting the appliance, check that the supply voltage is the same as that stated on the appliance.
Ensure that the appliance is installed on a level surface.
Make sure the appliance is switched OFF for installation.
CONNECTIONS REQUIRED IN ADVANCE OF INSTALLATION
ELECTRICAL CONNECTION
Please ensure a 230/240V 16A power socket is located within 1m of the product. The electrical connection should be
accessible during product installation so that the connection can be made to the product easily.
WATER CONNECTION
Please ensure a water connection is located within 1m of the product. The water connection should be one of the
following:
A male ¾ inch BSP connection (same as a standard supply for a washing machine)
A male ½ inch BSP connection (Fig 33)
Both the water and electrical connections should be accessible during product installation so that the connections can
be made to the product easily.
BUILDING THE PRODUCT SURROUND/ENCLOSURE
This product can be built into a wall, surround or structure. Please take note of the product dimensions (Fig.1) and build
your wall, surround or structure accordingly. Suitable clearance should be provided to allow the product to be installed
easily.
You are required to leave a minimum of 400mm from the base of the fuel bed to any shelf/enclosure above the product
(Fig. 2). This will allow enough space above the product to allow the flame effect to form fully and not to be obstructed.
When determining a location for the product, ensure that the unit will not be susceptible to drafts, vents, ceiling fans and
other air currents. Similar to a candle, large movements of air will affect the unit's ability to create and maintain the flame
effect. If the desired location is susceptible to significant air movement, i.e. air vents, the different installation options
illustrated in Fig 2 can be used.
VENTILATION
This product needs free ventilation from underneath to operate correctly. There are slots on the underside of the product
to allow this free air through the product. The free ventilation helps keep the electronic components cool and allows the
mist to rise and leave the product. Please see Fig 3 & 4 for examples of the required ventilation. Please take note of the
requirement for a ventilation opening on the shelf where the product sits, to allow a clear path for the air to get to the
product.
CAS500P-RGB-EU Free Ventilation Area: Minimum 210cm
CAS1000P-RGB-EU Free Ventilation Area: Minimum 420cm
MAKING THE WATER CONNECTION
It is recommended that you consult a qualified plumber to ensure a safe and secure installation.
Two adaptors have been supplied with the product to connect the ¼" blue PVC pipe of the product to mains water (Fig
33.1). Either the white ½ inch or the grey ¾ inch adaptor can be used to connect the product to the mains. For reference,
the ¾ inch adaptor is the same connection used on most washing machine supplies. Once the correct mains water
connection has been installed, follow the steps below to connect your product to the water supply.
CAS500P-RGB-EU,
Model No:
230V
P
0.24
Nom
P
0.24
min
P
0.24
max
-
-
P
0.21
Nom
CAS1000P-RGB-EU
240V
230V
0.26
0.47
0.26
0.47
0.26
0.47
-
0.22
0.43
2
2
5
240V
0.51
kW
0.51
kW
0.51
kW
-
0.44
W

Publicidad

loading

Este manual también es adecuado para:

Optimyst cassette 1000Cas500p-rgb-euCas1000p-rgb-eu