Descargar Imprimir esta página

Contest VPAR-70DW Guia Del Usuario página 22

Proyectores arquitectónicos blanco dinámico ip66 7/12/18 leds 2700 - 6000 k - 70/120/150 w - 25

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

English
6.6 - Power supply booster :
To overcome the lack of power of the line or the voltage drop due to a long cable length, it is necessary to be able to boost the power supply.
To do this, you will need to use a junction box and separate the DMX coming out of the hybrid cable at the end of the line and isolate the power
supply. A new mains power supply can then be injected into one or more chains of projectors on hybrid connectors at the outlet of the box as
shown in the figure below.
1m
+45°C
-20°C
architectural-lighting.eu
DMX/POWER IN
Distributed by HITMUSIC SAS
AC 100-240V 50/60Hz
FRANCE
DMX/POWER OUT
FUSE: T4A/250V 150W
MADE IN CHINA
IN
Booster power IN
16 A (3500W max)
CAUTION !
The sum of the powers of the different lines must
not exceed the power of the Power input (3500W).
The power per line is limited to the characteristics
of each of the devices, see table in the section on
chaining of projectors.
Hybrid
Power +
DMX IN
(Line output)
Booster
power IN
Page 22
VPAR-DW -
MAX: 9A
OUT
L
N
D+
GND
D-
1x IpBox-p6 box
1x VC-Start/3 cable
3x VC-End1/3 cable
1x FastCon-1333POW
1x FastCon-1333DMX
L
N
D+
GND
D-
IP66 architectural projectors with 7/12/18 Dynamic white LEDs
IN
3 x Hybrid
Power + DMX OUT
IP plug
1m
+45°C
-20°C
architectural-lighting.eu
DMX/POWER IN
Distributed by HITMUSIC SAS
AC 100-240V 50/60Hz
FRANCE
DMX/POWER OUT
FUSE: T4A/250V 150W
MADE IN CHINA
MAX: 9A
IN
IN
OUT
ATTENTION !
Outgoing power supply
OUT to be isolated from the
Booster power supply IN
OUT

Publicidad