Connect wiring.
1 7
Connect power
cable to wiring
plate (from
parts bag) using
UL approved
connector.
Connect house
wiring to fan
wiring. Refer to
wiring diagram
for connection
details (see at bottom of page). Use screw
(from parts bag) to secure wiring plate to
fan housing. Re-install wiring panel and
secure with screw from parts bag.
Remove old
1 4
fan and prepare
ceiling.
Enlarge ceiling opening (if
necessary) to 9¾" parallel to
joist) by 10½" (perpendicular
to joist). (Some models have
a cut-out template on side of
carton or on grille packaging materials.)
Existing fan housings are typically attached to the structure:
• with screws, nails, or staples, which must be removed.
• with hangers or rails which are fastened to joists and must be removed along
with housing.
A pry bar may be needed to remove the old housing.
Leave ductwork and wiring in place.
Connect wiring.
1 6
Connect power cable to wiring plate
(from parts bag) using UL approved
connector. Connect house wiring to
fan wiring. Refer to wiring diagram for
connection details (see below). Use
screw (from parts bag) to secure wiring
plate to fan housing. Re-install wiring
panel and secure with screw from parts
bag.
RETROFIT INSTALLATION
1
WIRING DIAGRAM
120 VAC LINE IN
Humidity Control Switch
(Model 82W)
Note: Refer to 82W instruction for additional installation details.
10½-in.
9¾-in.
RECEPTACLE
BLACK
WHITE
GROUND
(bare)
WIRING PLATE
3
Finish ceiling.
1 8
Then continue with Step 9.
Fold mounting ears
1 5
flat against housing.
JOIST