Descargar Imprimir esta página

EUCHNER SGP-TW AS1 Serie Manual De Instrucciones página 5

Interruptor de seguridad
Ocultar thumbs Ver también para SGP-TW AS1 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Safety Switch SGP-TW...AS1 (Twin)
Fig. 2: Changing the actuating direction
1. Remove the screws from the actuating head.
2. Set the required direction.
3. Tighten the screws with a torque of 0.6 Nm.
4. Cover the unused actuating slot with the en-
closed slot cover.
Electrical connection
The safety switch is connected to the bus system
with a 4-pin connecting cable with M12 plug connec-
tor via a passive AS-Interface distribution box with a
yellow and black AS-Interface cable.
View of safety switch
plug connector
1 AS-Interface +
4
2 Auxiliary voltage 0 V
3 AS-Interface -
4 Auxiliary voltage 24 V
1
Fig. 3: Terminal assignment of M12 plug connector
The following information applies to devices
with plug connector:
Check that the plug connector is sealed.
f
Function test
WARNING
Fatal injury due to faults during the function test.
Before carrying out the function test, make sure
f
that there are no persons in the danger zone.
Observe the valid accident prevention regula-
f
tions.
Check the device for correct function after installa-
tion and after every fault.
Proceed as follows:
Mechanical function test
The actuator must slide easily into the actuating
head. Close the guard several times to check the
function. The function of any manual releases (except
for the auxiliary release) must also be tested.
Electrical function test
1. Switch on operating voltage.
2. Close all guards and activate guard locking.
The machine must not start automatically.
¨
It must not be possible to open the guard.
¨
3. Start the machine function.
It must not be possible to release guard locking
¨
as long as the dangerous machine function is
active.
4. Stop the machine function and release guard
locking.
The guard must remain locked until there is no
¨
longer any risk of injury (e.g. due to movements
with overtravel).
It must not be possible to start the machine
¨
function as long as guard locking is released.
Repeat steps 2 - 4 for each guard.
Inspection and service
WARNING
Danger of severe injuries due to the loss of the
C
D
safety function.
B
A
If damage or wear is found, the complete switch
f
and actuator assembly must be replaced. Re-
placement of individual parts or assemblies is
not permitted.
Check the device for proper function at regular
f
intervals and after every fault. For informa-
tion about possible time intervals, refer to
EN ISO 14119:2013, section 8.2.
Inspection of the following is necessary to ensure
trouble-free long-term operation:
Correct switching function
f
Secure mounting of all components
f
Damage, heavy contamination, dirt and wear
f
Sealing of cable entry
f
Loose cable connections or plug connectors.
f
Info: The year of manufacture can be seen in the
bottom, right corner of the type label.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
3
correct use stated above, or if the safety regula-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
2
the warranty void.
Notes about
The following information applies to devices
with cable entry:
For use and application as per the requirements
of
a copper wire for the temperature range
60/75 °C must be used.
Declaration of conformity
The EU declaration of conformity can be found at
www.euchner.com. Enter the order number of your
device in the search box. The document is available
under Downloads.
Service
If servicing is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
E-mail:
support@euchner.de
Internet:
www.euchner.com
Technical data
Parameter
Housing material
Degree of protection
Mechanical life
Ambient temperature
Degree of contamination
(external, acc. to EN 60947-1)
Installation orientation
Approach speed, max.
Extraction force
Retention force
Actuating force, max.
Actuation frequency
Switching principle
Connection
Weight
AS-Interface data acc. to
AS-Interface specification 2.1
Operating voltage, AS-Interface DC 22.5 ... 31.6 V
Total current consumption,
max.
Valid AS-Interface addresses
AS-Interface inputs
Positively driven contact 1
Positively driven contact 2
AS-Interface outputs
D1
D2
AS-Interface Power LED
AS-Interface Fault LED
Characteristics acc. to EN ISO 13849-1
Monitoring of the guard position
B
10D
5
Value
Reinforced thermoplastic
IP67, mating connector inserted
2 x 10
operating cycles
6
-20 ... +55 °C
3 (industrial)
Any
20 m/min
25 N
10 N
25 N
6,700/h
2 positively driven contacts,
slow-action switching contact
Plug connector M12, 4-pin
Approx. 0.5 kg
EA code: 7
ID code: B
45 mA
1 - 31
Acc. to AS-Interface Safety at
Work
D0, D1
D2, D3
Red LED, 1 = LED on
Green LED, 1 = LED on
Green, AS-Interface power on
Red, offline phase or address 0
2 x 10
6

Publicidad

loading