IS Medical Grade
IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
CAUTION!
DO not connect to an ungrounded outlet. DO not use with extension cords or adapters that eliminate the connection to
ground. The isolation transformer is designed for indoor use only. Install the isolation transformer away from heat emitting
appliances such as radiators or heat registers. Do not install where excessive moisture or other conductive contaminants
are present. Do not use with life support appliances if a malfunction or failure could cause failure or significantly alter the
performance of the life-support device. Do not use this equipment within oxygen-enriched atmospheres or within 0.3 m at a
point from which an oxygen-enriched atmosphere is intentionally ventilated. This equipment is provided with multiple socket-
outlets for connection of electrical equipment which may create a system that could result in a reduced level of safety. For
additional requirements that are applicable to the ME system, the responsible organization should refer to IEC 60601-1.
Installation
1. Connect Your Isolation Transformer
to Your AC Power Line
Plug the power cord into a standard, 3-wire
grounded, 120V AC, 60 Hz utility outlet.
Note: The isolation transformer only meets UL60601-1
when plugged into a hospital-grade outlet.
2. Connect Equipment to Your Isolation
Transformer
Plug the AC power cords of your equipment
into your isolation transformer. Do not use
extension cords or adapters that eliminate the
connection to ground. Connect equipment
that requires a external connection to ground
to the isolation transformer's potential
equalization conductor, labeled " " on the unit.
3. Turn Your Isolation Transformer On
Flip the switch to provide clean AC power to
the isolation transformer's receptacles. "O" is
the ON position,"I" the OFF. Do not overload
your isolation transformer. Excess load on
the isolation transformer will cause its circuit
breaker to trip; if it does, the outlets will cease
to provide power. Reduce the load on the
isolation transformer down to your unit's
Output Power rating by unplugging excess
equipment, then depress the circuit breaker
rocker to reset the breaker and restore power.
Output floating, neutral output
conductor not grounded.
Tripp Lite is now part of Eaton
1000 Eaton Boulevard, Cleveland, OH 44122 United States
Eaton.com
© 2023 Eaton. All Rights Reserved
Owner's Manual
™
Maintenance
Your isolation transformer requires no routine
maintenance. There are no user-serviceable
parts inside your isolation transformer; do not
open it for any reason.
Specifications
Output Power
IS250HG
IS500HG
IS1000HG
IS1800HG
Medical/Hospital Grade
Protection
Your isolation transformer is UL 60601-1
listed, classified as Class 1,Type B, Continuous
Operation, Ordinary Equipment. The isolation
transformer is Faraday-shielded and reduces
the cumulative leakage currents of all connected
equipment below 100 microamps. As a further
safety measure, your isolation transformer
is equipped with a hospital grade plug and
receptacles to reduce the risk of accidental
equipment disconnection.
Eaton
Isolation Transformers
(Watts)
Outlets
250W
2 NEMA 5-15RHG
500W
4 NEMA 5-15RHG
1000W
4 NEMA 5-15RHG
1800W
6 NEMA 5-15/20RHG
(UL 60601-1 Listed)
PRODUCT REGISTRATION
Register your product today for a
chance to win an ISOBAR
protector in our monthly drawing!
Tripplite.Eaton.com/warranty
2-Year Limited Warranty
Seller warrants this product, if used in accordance with all applicable
instructions, to be free from original defects in material and
workmanship for a period of 2 years from the date of initial purchase.
If the product should prove defective in material or workmanship
within that period, Seller will repair or replace the product, in its sole
discretion. To obtain service under this warranty you must obtain a
Returned Material Authorization (RMA) number from Tripp Lite or an
authorized Tripp Lite service center. Products must be returned to
Tripp Lite or an authorized Tripp Lite service center with transportation
charges prepaid and must be accompanied by a brief description of the
problem encountered and proof of date and place of purchase.
This warranty applies only to the original purchaser who must have
properly registered the product within 10 days of purchase.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE
RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER
MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY
EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED
BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL
WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN
DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND
THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND
CONSEQUENTIAL DAMAGES.
WARNING :The individual user should take care to determine prior
to use whether this device is suitable,adequate or safe for the use
intended. Since individual applications are subject to great variation, the
manufacturer makes no representation or warranty as to the suitability
or fitness of these devices for any specific application.
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and
identification, your Tripp Lite product has been assigned a unique series
number. The series number can be found on the product nameplate
label, along with all required approval markings and information. When
requesting compliance information for this product, always refer to the
series number. The series number should not be confused with the
marking name or model number of the product.
Product Registration
Visit tripplite.eaton.com/warranty today to register your new Tripp Lite
product. You'll be automatically entered into a drawing for a chance to
win a FREE Tripp Lite product!*
* No purchase necessary. Void where prohibited. Some restrictions
apply. See website for details.
Tripp Lite has a policy of continuous improvement. Specifications are
subject to change without notice.
surge
®