5.3 Self-priming
When switched on for the first time after installation, the pump will start self-priming.
When the pump performs self-priming, it will count down from 1500s and stop automatically when the
system detects the pump is full of water, then the system will recheck for 30s again to make sure the self-
priming is completed.
User can exit self-priming manually by pressing
default Manual-Inverter mode at the initial startup. If the user exits the self-priming in the subsequent
startup, the pump will return to the previous state before the last shutdown.
Remark:
The pump is delivered with self-priming enabled. Each time the pump restarts, it will perform self-priming
automatically. User can enter the parameter setting to disable the default self-priming function (see 5.10)
If the default self-priming function is disabled, and the pump has not been used for a long time, the water
level in the strainer basket may drop. User can manually activate the self-priming function by pressing both
for 3 seconds, the adjustable period is from 600s to 1500s (default value is 600s). After the
manual self-priming is completed, the pump will return to the previous state before activating the manual
self-priming. If the pump has entered the Auto-Inverter mode previously, the pump will perform self-
learning for 180s to redefine the adjustable flow range after the manual self-priming.
User can press
for more than 3 seconds to exit the manual self-priming, and the pump will run the
same as the manual self-priming is completed.
5.4 Backwash
User can start the backwash or fast re-circulation in any running state by pressing
Time
Running capacity
Exit backwash:
When backwash mode is on, user can hold
state before backwash. If a speed limit is set by the user, the running capacity of the backwash will not
exceed the set speed limit. (see 5.9)
5.5 Manual-Inverter Mode (Easiest operating mode)
Default
Setting range
180s
Press
seconds for each step
100%
80~120%, enter the parameter setting (see 5.10)
for 3 seconds to exit, the pump will return to the previous
for more than 3 seconds. The pump will enter the
or
to adjust from 0 to 1500s with 30
.
7