6. TROUBLESHOOTING
If an error occurs with a charging session in progress, this will be interrupted and the socket will
be unlocked to allow you to disconnect the plug.
The following table provides a list of errors that can occour with the troubleshooting.
If the error persists, please contact Customer Service providing the wallbox serial number on
the product label to receive further information.
Error Code
Error Description
100
Missing power supply
101
Operating temperature limit exceeded
102
Hardware fault, communication error between MCU and MPU
103
Hardware fault, ground protection device error
104
Hardware fault, residual current monitor AC error
105
Hardware fault, ground protection device error
106
Internal meter error, invalid read values from MPU
107
DPM meter error, invalid read values from MCU
108
Configuration error, incoherent values between db and
RotarySW
109
Master RS485 communication lost by slaves
200
SuperCap voltage below a threshold
300
Incoherency between contactor command and feedback
301
Short circuit detected on the Control Pilot line
302
State E or F set on the Control Pilot line
303
Control Pilot disconnected
304
Proximity Pilot disconnected
305
Broken Proximity Pilot detected
306
Diode fault detected on Control Pilot line
307
Control Pilot disconnected
308
Incoherency between motor command and feedback, or motor
in error state
309
Motor check error during EVSE initialization phase
310
Hardware check error detected before charging
311
Hardware check error detected after charging
312
Emergency stop received from the MPU
313
Current detected during charging, with 100% duty cycle on the
Control Pilot line
314
Plug not removed (within a timeout) after the charging phase
has been stopped
315
Current over limit on phase L1
316
Current over limit on phase L2
317
Current over limit on phase L3
318
Voltage below a threshold on phase L1
319
Voltage below a threshold on phase L2
320
Voltage below a threshold on phase L3
400
State A detected on the Control Pilot line in pilot simplified case
Troubleshooting
Check if the dedicated wallbox circuit breaker in the
electrical panel is ON
When the temperature decreases below the treshold the
error clears itself
Restart the wallbox
Restart the wallbox
The error will clear itself when the session ends
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Restart the wallbox
Disconnect the charging cable from the wallbox, then
restart it
Restart the wallbox
Remove the plug. If the error persists restart the wallbox
Remove the plug. If the error persists restart the wallbox
Remove the plug. If the error persists restart the wallbox
Remove the plug. If the error persists restart the wallbox
Remove the plug. If the error persists restart the wallbox
Remove the plug. If the error persists restart the wallbox
Remove the plug. If the error persists restart the wallbox
Remove the plug. If the error persists restart the wallbox