Descargar Imprimir esta página

PEERLESS Smartmount D-FPF-220S Instalación Y Ensamblaje página 5

Soporte universal de pared plano para pantallas planas lcd de 23' a 46'
Ocultar thumbs Ver también para Smartmount D-FPF-220S:

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation to Solid Concrete or Cinder Block
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
Make sure that wall plate (AA) is level, use it as a
1
template to mark four mounting holes. The top mounting
slots should be located 4.07" (103 mm) above the
desired screen center as shown in figure 1.1 on page 4.
Drill four 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (65 mm). Insert anchors (DD) in holes flush with
wall as shown (right). Place wall plate over anchors and
secure with #14 x 2.5" screws (CC). Level, then tighten
all fasteners.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
• Always attach concrete anchors directly to load-
bearing concrete.
• Never attach concrete anchors to concrete covered
with plaster, drywall, or other finishing material. If
mounting to concrete surfaces covered with a finishing
surface is unavoidable, the finishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker than
5/8", custom fasteners must be supplied by installer.
(Not evaluated by UL)
INCORRECT
wall
plate
plaster/
dry wall
CORRECT
concrete
wall plate
plaster/
dry wall
WARNING
1
Drill holes and insert anchors (DD).
2
Place plate (AA) over anchors (DD) and secure with screws (CC).
3
Tighten all fasteners.
DD
concrete
AA
5 of 24
AA
CC
CC
ISSUED: 09-07-07 SHEET #: 202-9223-1
concrete
surface
DD
DD

Publicidad

loading