Operating Instructions
Read Heads/Actuators CMS for Safety Relays ESM
Service and inspection
Remove iron swarf from the read head and actuator
at regular intervals.
Use only solvent-free cleaning agents for cleaning
the actuators and read heads.
Regular inspection of the following is necessary
to ensure trouble-free long-term operation:
Correct switching function
f
Secure mounting of components
f
loose connections.
f
In the event of damage or wear, the damaged
system component must be replaced.
Exclusion of liability under the
following circumstances:
Incorrect use
f
Non-compliance with safety regulations
f
Installation and electrical connection not per-
f
formed by authorized personnel
failure to perform functional checks.
f
Declaration of conformity
The EU declaration of conformity can be found at
www.euchner.com. Enter the order number of your
device in the search box. The document is available
under Downloads.
Service
If servicing is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
E-mail:
support@euchner.de
Internet:
www.euchner.com
Technical data
Parameter
Value
Read heads
Housing material
Fiberglass reinforced PPS
Ambient temperature
-20 ... +60 °C
Ambient temperature only
-20 ... +80 °C
CMS-R-BZD...
Degree of protection
IP67
Installation orientation
Any, alignment with actuator
should be kept in mind (markings)
Connection
Molded cable with cable end
sleeves/plug connector M8,
4-pin/molded cable with plug
connector M12, 8-pin
Switching voltage
35 V DC
Switching current I
max.
0.1 A
e
Built-in fuse
100 mA (per safety contact)
Rated conditional short-circuit
100 A
current
1)
Contact status indication (only CMS-R-AZA)
Switching voltage
35 V DC
Switching current I
max.
0.02 A
e
Monitoring contact (only CMS-R-BZD)
Switching voltage
35 V DC
Switching current I
max.
0.1 A
e
Switching frequency f
at I
max
min
5 Hz
10 mA
1)
Switching frequency f
at
max
0.1 Hz
nominal current 8 A
1)
Switching delay from state
26 ms
change
1) 2)
Method of operation
Magnetic, reed contact
Mechanical life
100 x 10
operating cycles
6
Vibration resistance
10 ... 55 Hz, amplitude 1 mm
Shock resistance
30 g/ 11 ms
EMC compliance
Acc. to EN 60947-5-3
Center offset m from actuator ± 2.5 mm at distance s = 3 mm
Operating distance s
ao
Release distance s
See combination options table
ar
Switching contacts
Classification acc. to EN 60947-5-3
CMS-R-BZB.../CMS-R-BZD...
CMS-R-AZA.../CMS-R-AZC...
Fusing of the power supply and the safety contacts
External contact fuse
Fuse 10 A gG
1)
Actuator
Housing material
Fiberglass reinforced PPS
Ambient temperature
-20 ... +60 °C
Ambient temperature only
-20 ... +80 °C
CMS-M-BH
Degree of protection
IP67
Installation orientation
Any, alignment with read head
should be kept in mind (markings)
Method of operation
Magnetic
Vibration resistance
10 ... 55 Hz, amplitude 1 mm
Shock resistance
30 g/ 11 ms
Center offset m from read
± 2.5 mm at distance s = 3 mm
head
Operating distance s
See combination options
ao
Release distance s
ar
Characteristics acc. to EN ISO 13849-1
Category
4
1)
Mission time
20 years
Performance Level
e
1)
B
20 x 10
operating cycles
6
10D
1) Parameter dependent on the evaluation units ESM-BA2.. and
ESM-BA3..
2) Corresponds to the risk time according to EN 60947-5-3. This is
the maximum OFF time for the safety outputs following removal
of the actuator.
5
Design CMS-.-A...
Y
Approach
direction
Z
Design CMS-.-B...
Y
Approach
direction
Fig. 1: Alignment of read head and actuator
M3D36AS1
M3D88AS1
table
Alignment marking
X
Alignment marking
X
Z