LED Fault Indicator Diagnostics
Error Message
Error code
LED BLINKS
5
(1,1)□ □
9
(1,2)□ □□
10
(1,4)□ □□□□
6
(1,5)□ □□□□□
117
(2,2)□□ □□
111
(2,3)□□ □□□
(2,4)□□ □□□□
110
116
(3,1)□□□ □
(3,2)□□□ □□
100
(3,2)□□□ □□
101
105
(3,3)□□□ □□□
115
(3,5)□□□ □□□□□
Explanation
Over Current
Over Temperature
Under Voltage
Over Voltage
Emergency reverse
switch
MAIN_SHORT
MAIN_DRI
INTERLOCK
BRAKE
BRAKE
PRECHARGE
HPD
D
3
Possible cause
The controller detects excessive
current,
Check whether there is a short
circuit in the motor phase line.
power off and restart.
The controller temperature
exceeds 95 ° C,
The controller works continuously
under a high load, or the ambient
temperature is too high,
power off and restart.
The supply voltage is below 17V
Power supply battery
undervoltage, power off and
restart.
The controller detected an
overvoltage
Check whether the power supply
voltage is normal. Power off and
restart.
Emergency reverse switch failure
Before power-on, the Emergency
reverse switch be engaged,
Release the Emergency reverse
switch and power on again.
Main relay short circuit
Main relay drive circuit failure
INTERLOCK failure
Before power-on, the interlock
switch be engaged, and the reset
the tiller and powered on again
Opening of electromagnetic brake
is abnormal.
Electromagnetic brake controller
circuit failure, replace the
controller.
The electromagnetic brake shuts
down abnormally.
Electromagnetic brake wiring is
not reliable, or the drive circuit
fault, power off restart.
The Precharge circuit is abnormal
HPD failure.
Before power-on, the accelerator
be activated. Release the
accelerator and power on the
device again.
REV. 09/2022