SECURITY DISTANCES
From NOT combustible object :
−
A > 500 mm B > 100 mm C > 35 mm D > 1000 mm
From combustible object and from principal wall in rein forced concrete :
−
A > 1000 mm B > 200 mm C > 200 mm D > 1000 mm
The minimal distance between the stove and every object around it is 1 meter
Connection
Before connection check the technical data reported in the technical plate and control that
they correspond to the ones required in the order.
All heating biomass equipments especially wood and pellet stove have to evacuate the
combustion products in a flue, built in conformity with the normative in force.
•
The following instructions describe „ informations for a good installation „ and refer to a
normative in force but they are not to be consider exhaustive for installations laws.
IT-GB-FR-ES mod. 502-502X-502L-502LX
Always measure from external
equipment surface