ELECTRICAL CONNECTION

The appliance is equipped with an electrical cable H05RR-F 3x0.75 mm² with European
Plug. The connection is "Y" type so every maintenance or substitution has to be done by
a qualify staff.The electric cable has to be connected to a socket 1N 230V AC 50Hz and
it hasn't to touch any warm or sharp surfaces of the appliance..
The appliance should be connected with a grounding system

COMBUSTION AIR INTAKE DIRECT FROM ENVIRONMENT

It's advisable to read, follow and respect what indicated in Normative and prescriptions.
The equipment should have the necessary air for combustion, supplied by external air
intake.
The air intake should have the following characteristics :
a)
Total free section min 200 cm²;
b)
Connected directly with installation environment ;
c)
Protected with grate or lath ( attention to not reduce the min. section required on
point a ) and placed so that to avoid obstruction.
The air inflow can be also supplied from the adjacent room but the air intake should be
always free and connecter ahead outside. No chimney or suction hood should be present
in the environment of installation or into the nears ones.
Inside the adjacent room the air intake should have the characteristics required in letter a
and c .
The adjacent room can not be use as garage, warehouse of combustible material etc..

COMBUSTION AIR INTAKE DIRECT FROM OUTSIDE

It's advisable to read, follow and respect what indicated in Normative and prescriptions.
To take air direct from outside it's necessary :
Use metal tubes of diameter Ø50 mm or more; resistant to temperature of al least
200°C in this area of connection to the appliance.(See the connection schedule).
To guarantee a sufficient air influx, the connection's tube has not to be longer that
2÷3 mt. and it has not to have a lot of curves.
If the air intake is direct to outside, its output has a curve of 90° down with a
protection grill to avoid the introduction of small animals.
In case of closure device, it must open automatically at equipment's starting.
To not observe these instructions, it means that Your stove will have a bad
combustion and the lost of Your guarantee.
Protected with grate or lath ( attention to not reduce the min. section required on
point a ) and placed so that to avoid obstruction .
NOTE: The air inflow whole must be placed at the low.
NOTE : Extractor fans when operating in the same room or space as the appliance may cause
problems.
NOTE :The installation room should not be put in depressure by other appliances such as
suction hoods, chimneys, evacuation flues, present in the room itself or in the adjacent rooms,
which are in communication.