Descargar Imprimir esta página

Kenmore ELITE 625.382080 Manual Del Propietário página 6

Ocultar thumbs Ver también para ELITE 625.382080:

Publicidad

Idiomas disponibles

Idiomas disponibles

PLUMBING CODES
All plumbing must be completed in accordance with
national, state and local plumbing codes.
In the state of Massachusetts: The Commonwealth
of Massachusetts plumbing code 248-CMR shall
be adhered to. A licensed plumber shall be used
for this installation.
AIR GAP REQUIREMENTS
A drain is needed for Clean Rinse discharge water. A
floor drain, close to the Central Water Filtration
System, is preferred. A laundry tub, standpipe, etc.
are other drain options.
Secure valve drain hose in
place. Leave an air gap of 1-1/2" between the end of
the hose and the drain. This gap is needed to prevent
backflow of sewer water into the Central Water Whole
Home Filtration System.
Do not put the end of the
drain hose into the drain.
VALVE DRAIN REQUIREMENTS
Using the flexible drain hose (included), measure and
cut to the length needed.
Flexible drain hose is not
allowed in all localities (check your plumbing codes).
If
local codes do not allow use of a flexible drain hose, a
rigid valve drain run must be used. Purchase a com-
pression fitting (1/4 NPT x 1/2 in. minimum tube) and
1/2" tubing from your local hardware store. Plumb a
rigid drain as needed (see Figure 3, below).
NOTE: Avoid drain hose runs longer that 30 feet.
Make the valve drain line as short and direct
as possible.
It is recommended that the Central Water Whole Home
Filtration System be installed near a drain. However, if
a drain is not available, it is still possible to operate the
Central Water Whole Home Filtration System in a
manual Clean Rinse mode. See "Operating in Manual
Clean Rinse Mode" section. The automatic Clean
Rinse function must be disabled if the Central Water
Filtration System will not be connected to a drain.
CONNECTING
VALVE TO DRAIN
DrainI
Fitting
/
ose2%--
Clamp
'_-_-_
_-_--
Valve
Drain -........_.
Hose
Tie or wire
tubing in
place
Drain grate with 1"
dia. hole in center
To drain point other
than floor drain.
Support tubing in
place as needed.
Install adaptor
elbow using hose
clamp. Aim noz-
zle down toward
center of drain
1-1/2"
air gap
FLOOR
DRAIN
SUBSTITUTING
RIGID DRAIN LINE
1/4 NPT Threads
_,j/i_J
Barbs
._/_,.;o_:/
1/2" Outs ide Dis.
_,,Zz_iC"_'&.." (i/__ _
Copper Tube
blip
"
_
.... (_.._/_/7_/._
(not included)
Cut barbs from
/..._.J_f_
A
.
drain fitting (pull
-_
"_L/-'r'b'_
-I
clip to remove fit-
_'---__._¢
_..
ting from valve)
Comp Fitting. 1-7"_ _-/
_..
"
NPT x 1/2" O.D.
Tube (not included)
air
LAUNDRY
TUB
STANDPIPE
Figure 3
Questions?
Call The Kenmore
Water Line 1-800-426-9345
or visit KenmoreWater.com

Publicidad