able to remove the high-efficiency filters.
-
You can wash the high-efficiency filter with warm water (Fig. 18). However, it is
recommended to vacuum or shake it out, to prevent the filter from getting wet or damp
and affecting the performance of the vacuum cleaner.
-
If you decide to wash it, make sure it is completely dry before installing it again on the
device.
-
Filters cannot be washed inside a washing machine nor dried with a hair dryer.
-
Do not brush the filter.
-
To empty the dust tank, press the dust tank lower opening button, open it and empty it.
Fig. 19
Cleaning the Jaliscazo brush
Fig. 20
-
Move the rotary brush release button with the finger toward the arrow and remove the
cover on the same side of the brush.
-
Remove one end of the brush as shown on the image.
-
It is important to clear and clean all the residues left in the brush rotary axis.
-
If you decide to wash the brush, you must air dry all the pieces. Assemble the pieces back
in order to use the brush again.
Watertank cleaning
-
To clean the water tank, fill it with clean water, shake it, and empty it.
-
The mop is washable; therefore, it is suggested to wash it after every use.
-
Replace the cloth after 20-30 uses, depending on the use.
-
When the mop cloth is used for a long time, it is possible that the water output is affected.
This can be avoided by cleaning both the mop and water tank regularly.
How to remove the battery
Press the battery release button and tremove the battery as shown on the image. Store the
battery in a plastic bag and leave it in a dry place. Fig. 21
Storing the device
-
If the vacuum cleaner is not going to be used for a long time, remove the battery from the
product and store it in a dry and safe place.
Maintenance indicator
-
The full tank icon or the obstructed filter icon will be displayed if the device has not been
properly and frequently maintained. Fig. 22
56
7. TROUBLESHOOTING
Problem
Possible cause
The motor does not operate
The battery does not work
any longer.
The metallic tubes, floor
brushes, batteries or the
device itself are not properly
assembled.
The suction power has been
The dust tank is full.
reduced and the appliance
The filter has too much dust.
makes a lot of noise.
The electric rotary brush inlet
Fig. 23
is obstructed or the brush is
blocked.
Insufficient operating time
Insufficient charge time.
after charge.
The battery is old.
(The battery life may vary
according to the room
temperature).
8. ERROR CODES
Code
Problem
E1
The device turns off and does not
charge
E2
The device does not charge
E2
The device does not charge
The device turns off
E3
The device turns off and displays E3
E5
The device turns off and displays E5
E6
The device turns off and displays E6
ENGLISH
Solution
Charge the vacuum cleaner.
Make sure all parts of
the device are correctly
assembled.
Clean the dirt.
Clean or replace the filter.
Clean the dust inside the
electric rotary brush.
Fully charge the battery
following the instructions in
this manual.
Batteries are easily
recycled. Go to the closest
maintenance point and buy
new batteries.
Cause
Short circuit
The charger voltage is below 36.3 V
The charger voltage is below 32.1 V
Low battery
The motor short-circuits when the
battery is low
Main motor overload (second level)
Main motor overload
CONGA ROCKSTAR 2500 X-TREME ULTIMATE ERGOWET