Cleaning the Jaliscazo brush
Fig. 10
1.
Move the rotary brush release button with the finger toward the arrow and remove the
cover of one of the ends of the brush.
2.
Take one end of the brush out as shown on the image.
-
It is important to clear and clean all the residues left in the brush rotary axes.
-
If you decide to wash the brush, you must air dry all the pieces. Assemble the parts in
reverse order of disassembly so that the brush can be used again.
How to remove the battery
Press the battery release button and remove the battery as shown in figure 11. Store the battery
in a plastic bag and leave it in a dry place.
Device storage
Remove the battery and store it in a safe, dry place if the device is not going to be used in a
long period of time.
Maintenance indicator
If maintenance has not been carried out frequently enough, the appliance will display a full
tank or clogged filter icon on the screen. Fig. 12-13
6. TROUBLESHOOTING
Problem
Possible cause
The motor does not operate
The battery does not work
any longer.
The metallic tubes, floor
brushes, batteries or the
device itself are not properly
assembled.
The suction power has been
The dust tank is full. Fig. 12
reduced and the appliance
The filter has too much dust.
makes a lot of noise.
Fig. 13
The electric rotary brush inlet
is obstructed or the brush is
blocked. Fig. 14
46
Solution
Charge the vacuum cleaner.
Make sure all parts of
the device are correctly
assembled.
Clean the dirt.
Clean or replace the filter.
Clean the dust inside the
electric rotary brush.
Insufficient operating time
Insufficient charge time.
after charging the device.
The battery is old.
(The battery life may vary
according to the room
temperature).
7. ERROR CODES
Code
Problem
E1
The device turns off and does not
charge.
E2
The device does not charge.
E2
The device does not charge.
The device turns off.
E3
The device turns off and displays E3.
E5
The device turns off and displays E5,.
E6
The device turns off and displays E6,.
E9
The device turns off and displays E9,.
E7
The device stops working or does not
turn on and shows E7.
E8
The device turns off and displays E8,.
High-
The device stops or does not switch
efficiency
on. Fig. 13
filter
indicator
blinks
The filter set
It works normally. Fig. 12
logo flashes.
The brush
The long brush and motor stop
icon flashes
working. Fig. 14
ENGLISH
Fully charge the battery
following the instructions in
this manual.
Batteries are easily
recycled. Go to the closest
maintenance point and buy
new batteries.
Cause
Short circuit
The charger's voltage is below 36.3 V
The charger's voltage is below 32.1 V
Low battery
The motor short-circuits when the
battery is low
Main motor overload (second level)
Main motor overload
Temperature too high or low
Battery fault (first level)
NTC error (thermistor short circuit)
High-efficiency filter not installed
The dust tank or the inlet filter is
blocked
Blocked long brush
Long brush full of hair
CONGA ROCKSTAR 1600 ADVANCE