Requirements for compliance with UL 294
This section contains information and instructions required for UL compliance. To make sure the
installation is UL compliant, follow the instructions below in addition to the general information
and instructions provided throughout this document. In cases where pieces of information
contradict each other, the requirements for UL compliance always replace general information
and instructions.
Performance levels for access control
This section contains performance level information required for UL 294 compliance.
Feature
Destructive attack test
Security
Endurance
Standby power
Supported readers
•
For UL 294, compatibility with the following readers has been verified by UL:
AXIS A4020-E, AXIS A4120–E and HID Signo 20.
Safety instructions
•
Shall be installed in accordance with Article 725.121 of the National Electrical Code,
ANSI/NFPA 70.
•
The Axis product shall be installed and serviced by a factory trained professional.
•
The Axis product shall be installed within the protected premises (secured area).
•
The Axis product shall be mounted indoors. Outdoor use has not been evaluated or
approved by UL.
•
All interconnecting devices shall be UL listed and Class 2 low-voltage power limited.
•
All power outputs are Class 2 outputs.
•
All wiring methods shall be performed in accordance with ANSI/NFPA70, local codes and
authorities having jurisdiction.
•
Recommend to use UL recognized grounding wire, a size of 14-16 AWG, yellow/green
color. Crimp the cable on the non-insulated wire pressure ring terminal which is being
delivered as a spare part of the product. Important to use proper crimping tool and
techniques to ensure the safety of product and user.
•
When the Axis product has reached the end of its useful life, dispose of it according
to local laws and regulations. The product should not be disposed of together with
household or commercial waste. See Disposal and recycling on page 3 .