Otherwise, the compressor restraint may break.
We DO NOT provide warranty services for damage caused by improper use!
1.0 SAFETY INSTRUCTIONS
Staff qualification for operation
 This unit may be used by children over the age of 8 and by individuals with reduced physical,
sensory or mental capabilities or a lack of experience and knowledge, provided that they are
supervised or have received instructions on the safe use of the unit and understand the risks
involved. Children must not play with the unit. Do not allow children to clean the unit without
supervision. Maintenance must only be carried out by specialist staff.
 Individuals who have to use this unit must be aware of the dangers that arise when working
with electrical equipment, especially in a damp environment.
 Individuals who must use this unit have read and understood the operating manual.
Staff qualification for maintenance and repair
 Any person working on the refrigerant circuit must have a certificate of competence issued by
an industry-accredited body demonstrating their expertise in the safe handling of refrigerants
by means of a method known in the industry.
 Maintenance may only be carried out in accordance with the unit manufacturer's
recommendations. Maintenance and repair work requiring the assistance of other skilled
personnel must be carried out under the supervision of a person responsible for handling
flammable refrigerants.
Units – safety instructions
 The unit is only intended for use with R-290 (propane gas) as refrigerant.
 The refrigerant circuit is sealed. Maintenance should only be carried out by a qualified
technician!
 Do not discharge the refrigerant into the atmosphere.
 R-290 (propane) is flammable and heavier than air. It first collects in low-lying areas, but can
be circulated by the fans.
 If propane gas is present or even suspected, do not allow untrained personnel to try to find
the cause.
 The propane gas used in the unit is odourless.
 The absence of odour does not mean that no gas has leaked.
 If a leak is detected, immediately evacuate everyone from the room, ventilate and notify the
local fire brigade to inform them that a propane gas leak has occurred.
Text reproduction:
!!! Caution!!!
1.
Before initial start-up, let the unit
stand upright
and stationary for at least 4 hours! This protects
the
compressor,
considerably and thus prevents a loss of cooling
capacity.
2.
The dehumidifier unit must always be
placed on the floor with PARTICULAR CARE!