Troubleshooting:
Faults
After the power plug is inserted, the power indicator
light is off and the compressor does not run
Compressor doesn't start, but there's a buzz
Compressor shuts down frequently
The temperature inside the freezer
does not reach the set temperature,
and the compressor does not stop.
Too much noise
The temperature inside is already very low,
but the machine still works.
No refrigeration
Esta marca indica que este producto no debe
eliminarse con otros residuos domésticos en
toda la UE. Para evitar posibles daños al medio
ambiente o a la salud humana por la eliminación
incontrolada de residuos, recíclelo de forma
responsable para promover la reutilización
sostenible de los recursos materiales. Para
devolver su dispositivo usado, utilice los
sistemas de devolución y recogida o póngase en
contacto con el minorista donde compró el
producto. Ellos pueden llevarse este producto
para reciclarlo de forma segura para el medio
ambiente.
Reasons
No power
Poor contact between power plug and socket
Low voltage
Voltage higher than 242V
Too many openings
Putting too many room temperature items at
one time, placing them too densely.
The frost layer is too thick
System leakage
Too much dirt on the surface of the condenser
The door is not closed
Improper thermostat gear
Ambient temperature is too high
The product is not placed stably
Fastener loose
Refrigeration pipeline vibrates
The cooling fan collides with other components
Improper thermostat gear
Refrigerant leak
Refrigeration system is blocked due to dirty
Refrigeration system is blocked due to ice
7/8
Method
Check the cause and wait for power
Check sockets and plugs
1. Shut down immediately, and restart
after the voltage is normal.
2. Add a voltage regulator
Reduce opening times
Reduce storage items, and leave appro-
priate space for items, which is conducive
to cold air circulation and heat exchange
Defrost in time
Repair
Shut down, clean the condenser
Close the door
Turn thermostat knob clockwise
Keep away from heat sources and
avoid direct sunlight
Re-leveling
Tighten it
Organize the pipelines to avoid
mutual collision
Adjust the fan position
Slowly turn the thermostat knob counter-
clockwise to the corresponding position
Leak detection, leak repair, evacuation,
refrigerant charging
Overhaul capillary, replace filter drier
Replace the filter dryer, evacuate again,
and fill with refrigerant
Mark
Self-test
Self-test
Self-test
Prof.
Self-test
Self-test
Prof.
Self-test
Prof.