Descargar Imprimir esta página

cecotec FORCECLIMA 9500 Soundless Heating Connected Manual página 35

Ocultar thumbs Ver también para FORCECLIMA 9500 Soundless Heating Connected:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
ENGLISH
thinner, or other solvents, as these can scratch and damage the tank and cause water
leakage.
-
Do not immerse the product in water or other liquids.
Cleaning the filter. Fig. 12
-
If the filter is clogged with dust, the effectiveness of the air conditioning will be reduced.
Make sure to clean the filter once every two weeks.
-
Cleaning the upper filter frame
-
Unscrew the screw attached to the filter at the rear with a screwdriver and remove the
filter.
-
Put the filter screen into warm water with neutral detergent (about 40 ºC / 104 ºC) and
dry it in the shade after rinsing clean. Make sure it is completely dry before reattaching it.
Replacing batteries
The remote control is powered by two AAA batteries. If the remote control does not respond,
replace the batteries as follows:
1.
Put the remote control face down and slide the tab outwards.
2.
Remove the batteries.
3.
Insert the batteries paying attention to polarity.
Storage
-
Store the device in well ventilated areas.
-
Unscrew the drain cap, unplug the water plug, and discharge the water in the water tank
into other water containers or directly tilt the body to discharge the water into other
containers.
-
Turn on the appliance, adjust it to low-wind ventilation mode, and maintain this state until
the drainage pipe becomes dry. This way, you will keep the inside of the body in a dry state
and prevent it from mildewing.
-
Turn off the appliance, unplug the power plug, and wrap the power cord around the
wrapping post. Install the water plug and the drain cap.
-
Remove the exhaust pipe and keep it properly.
-
Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place, keep it
out of the reach of children, and take dust control measures.
-
Remove batteries of the remote control and keep them properly.
-
Ensure that the body is placed in a dry place and keep all machine components properly.
Maintenance
Any person who is involved with working on or breaking into a refrigerant circuit should hold a
current valid certificate from an industry-accredited assessment authority, which authorises
their competence to handle refrigerants safely in accordance with an industry recognised
assessment specification.
68
FORCECLIMA 9500 SOUNDLESS HEATING CONNECTED
7. TROUBLESHOOTING
Problems
Possible causes
The air
There is no electricity.
conditioning
does not
The full-tank indicator will
work.
flash.
The room temperature is
too low or too high.
In cooling mode, the room
temperature is lower than
the set temperature; in
heating mode, the room
temperature is higher than
the set temperature.
In dehumidification mode,
the room temperature is
very low.
There is direct sunlight.
The cooling
Doors or windows are
effect is not
open; there are a lot of
good
people; or in cooling mode,
there are other sources of
heat.
The filter screen is dirty.
The air inlet or outlet is
blocked.
The device
The air conditioning is not
makes a lot
placed on a flat surface.
of noise
Compressor
There is frost.
does not
Protection against
work.
overheating system is
activated.
ENGLISH
Possible solutions
Turn it on after connecting it to a socket
with electricity.
Discharge the water inside.
It is recommended using the appliance in at
the temperature of 7-35 ºC.
Change the set temperature.
The appliance is in a room with a
temperature below 17°C.
Pull the curtain.
Close doors and windows.
Clean or replace the filter.
Clear obstructions.
Put the air conditioning on a flat and hard
place (to reduce noise).
Wait for 3 minutes until the temperature is
lowered, and then restart the appliance.
FORCECLIMA 9500 SOUNDLESS HEATING CONNECTED
69

Publicidad

loading