ELECTRIC CONNECTION (diagram B)
The electric connection must be performed by qua-
lified technicians in compliance with regulation of
each country. Before doing manipulations inside the device,
it must be disconnected from the electric supply.
Wrong connection could spoil the electronic circuit.
The manufacturer declines all responsability in dama-
ges caused by wrong connections.
Check if power supply is beetween 110-230V.
If you have purchased the unit without cables follow dia-
gram B.
• Use cables type H07RN-F for power supply and motor
connection with section 3G1 or 3G1,5 depending on the
power installed.
• Do the pump connection U, V and
• Do the power supply connection L, N and
The earth conductor must be longer than the others.
It will be the first one to be mounted during the as-
sembly and the last one to be disconnected during the
dismantling.
Use cable H05VVV-F 4x0.5 for IN-OUT and COMMUNICA-
TION connection.
• Use IN connector for the external input.
• Use OUT connector for the alarm monitor.
• Use COMUNICATION connector to connect 2 DPR fo-
llowing the wiring diagram FIG. D.
Connect the IN-OUT wires of both DPR MASTER in parallel
inside of a junction box to connect the external input and
the alarm monitor to both devices.
The earth conductors connections are compulsory!
CONTROL PANEL (diagram C)
The meanings of the different control panel elements are
summarized on the following tables, where:
• O means lit LED light.
• ( ( O ) ) means LED flashing.
DISPLAY
Is showed on screen instantaneous
OPERATION
pressure or instantaneous current con-
MODE
sumption.
Is displayed on screen the adjusted start
ADJUSTMENT
pressure.
MODE
Is displayed the adjusted rated current.
ALARM MODE Is displayed the alarm code.
STAND-BY
Are displayed 3 flashing dots.
MODE
BASIC
Is displayed the sequence of basic con-
CONFIG.
figuration parameters.
ADVANCED
Is displayed the sequence of advanced
CONFIG.
configuration parameters.
.
.
ACTION
LEDS
DISPLAY
O
( ( O ) )
O
( ( O ) )
O
( ( O ) )
O
( ( O ) )
START
PRESSURE
O
FLOW
O
( ( O ) )
ALARM
P-BUTTON TOUCH
click!
ENTER
HOLD
DOWN
click!
click!
UP
ARROW
3"
click!
DOWN
ARROW
click!
AMPERE
3"
18
ACTION
Is displayed on screen the instan-
taneous pressure in bar
Pump ON and is displayed on
screen the instantaneous pressure
in bar
Is displayed on screen the instan-
taneous pressure in psi
Pump ON and is displayed on
screen the instantaneous pressure
in psi
Is displayed on screen the instan-
taneous current consumption in
Ampere units
Pump ON and is displayed on
screen the instantaneous current
consumption in Ampere units
Is displayed the start pressure
Adjusting start pressure
It indicates positive flow
Ratified dry-running or overload
alarms
Dry-running alarm performing ART
or overload alarm preforming any
of the 4 restore attempts
ACTION
From state ON: any alarm is
restored.
From state OFF: system changes
to STATE ON, the pump starts.
From any configuration MENU:
the parameter value is accepted.
From state ON: unit OFF, relay
disconnection.
From state OFF: the pump starts
and keeps operating until the
push-button is released.
Pstart is displayed on the screen
for 3 seconds.
Increase the programming value.
Pstart adjustment mode.
Dicrease the programming value.
Is displayed on the screen instanta-
neous current consumption.
If it is already displayed then we
switch to instantaneous pressure
view.
Rated current adjustment.