Usage
1.
Press the Stud detection button (7) to enter the stud detection mode.
2.
Complete the calibration and place the device flat against the surface to be tested.
3.
Slowly move the detector across the surface in the direction you want to scan.
4.
If a stud is detected, the screen will display the wooden/metal stud icon
strength indication. The device emits a sound. The closer the device to the object, the stronger the signal.
AC detection mode
This mode is used only to detect live wires.
Calibration
1.
Press the AC wire detection button (2) to enter the AC detection mode.
2.
Place the device flat against the target surface.
3.
Press the AC wire detection button (2) to start calibration. The calibration will be carried out automatically. When the white part of the
display becomes dark, the calibration is completed.
4.
Remove the device from the surface and press Power/Back button (4) to exit the calibration mode.
Usage
1.
Complete the calibration and place the device flat against the surface to be tested.
2.
Slowly move the detector across the surface in the direction you want to scan.
3.
When the device detects a live wire, the screen will display the live wire icon
strength indication. The device emits a sound. The closer the device to the object, the stronger the signal. You can reduce the sensitivity
of the device multiple times to narrow the search area even more and locate the live wire with greater accuracy.
Specifications
Max. detection depth
Sound alert
Auto-off
Display
Operating temperature range
Power source
Dimension
Weight
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Do not touch the sensing area of the device during measurement in order to avoid mistakes, because the human body has conducting
properties. Do not exclusively rely on the detector to locate items behind scanned surfaces. Do not assume that there is no live cabling inside
a wall. Always use caution when nailing, cutting, or drilling in walls, floors, and ceilings that may contain live cabling. Calibrate the device
regularly following a routine schedule. Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any
kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Store the
device in a dry cool place. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt
to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention
immediately.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one
time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior
to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment
that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high
temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off
devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as
prescribed by your country's laws.
Levenhuk International Warranty
Levenhuk products, except for their accessories, carry a 5-year warranty against defects in materials and workmanship. All Levenhuk
accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles
you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions
are met.
For further details, please visit: www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.
, the value of the distance to the target, and the signal
, the value of the distance to the target, and the signal
live wiring: 50mm
ferrous metals: 120mm / non-ferrous metals: 100mm
wooden/metal studs: 38mm
+
5min
2.4" HD color screen, 240x320px
0... +50°C (operating), –10... +60°C (storage) /
32... +122°F (operating), 14... +140°F (storage)
rechargeable polymer lithium battery, 390mA
5V 1A DC adapter (not included)
Type-C USB cable (included)
63x25x139mm
138g