Installation
Instructions
DOOR ALIGNMENT
After leveling, make sure that doors are even at the top,
To make the doors even, adjust the refrigerator
door,
Using a 5/16" socket wrench, turn the door adjusting
screw to the right to raise the door, to the lefl to lower
it, (A nylon plug, embedded
in the threads of the pin,
prevents
the pin from turning unless a wrench is used,)
After one or two turns of the wrench, ()pen and close
the refrigerator
door and check the alignment
at the
top of the doors.
To removethebase
grille, openthedoo_s
andthen pullthe
grille straightout
5/16" Socket
/"
Wrench
--_1_
Raise
INSTALLING THE WATER LINE
(ON SOME MODELS)
BEFORE YOU BEGIN
When connecting a GE Reverse Osmosis Water System to
your refrigerator,
the only approved installation is with a
GE RVKIT,
If the water supply to the refrigerator
is from a Reverse
Osmosis Water Filfration System AND the refrigerator
also
has a water filter, use the refi_igerator's filter bypass plug,
Using the refiigerator's water filtration cm'tridge in
conjunction with the RO fiher can result in hollow ice
cubes and slower water Ilow from the water dispenser.
This water line installation
is not warranted
by the
refrigerator
or
icemaker
manufacturer,
Follow these
instructions
carefully to minimize
the risk of expensive
water damage,
Water hammer
(water banging in the pipes) in house
plumbing
can cause damage
to refrigerator
parts and
lead to water leakage or flooding
Call a qualified
plumber
to correct water hammer
before installing
the water supply line to the refrigerator.
BEFORE YOU BEGIN (CONT.)
To prevent burns and product
damage,
do not hook
up the water line to the hot water line.
If you use your refrigerator
before
connecting
the
water
line, make
sure the icemaker
power
switch is
in the OFF position.
Do not install
the icemaker
robing
in areas where
temperatures
fall below
freezing,
When using any electrical device (such as a power drill)
during installation,
be sure the device is insulated
or
wired in a manner
to prevent the hazard of electric
shock.
All installations
must be in accordance
with local
plumbing
code requirements.