Contents
SUBJEC T
PAGE
Pre-lnstallation Requirements
2
Electrical Requirements
2
Grounding Requirements
2
Water Supply Requirements
2
Drain Requirements
2
Rough-In Dimensions
3
Location Of Your Washer
3
Unpacking
3
Installation
4
Replacement Parts
4
PRE-INSTALLATION
REQUIREMENTS
Tools Required
for Installation:
1.
1/4 in. nut driver
2.
3/8 in. socket with ratchet.
3.
3/8 in. open end wrench.
4.
7/16 in. socket with ratchet.
5.
9/16 in. open end wrench.
6.
Channel-lock
adjustable pliers.
7.
Carpenter's level.
ELECTRICAL REQUIREMENTS
CIRCUIT- Individual, properly polarized and grounded
15 amp. branch circuit fused with 15 amp. time delay
fuse or circuit breaker.
POWER SUPPLY- 2 wire, with ground, 120 volt, single
phase, 60 Hz, Alternating Current. NOTE: The use of
this washer with
power created
by gas powered
generators, solar powered generators, wind powered
generators or any other generator other than the local
utility company is not recommended.
OUTLET RECEPTACLE- Properly grounded 3-prong
receptacle to be located so the power supply cord is
accessible when the washer is in an installed position.
NOTE: GFI (Ground Fault Interrupter) receptacle is not
required.
GROUNDING
REQUIREMENTS
Improper connection of the equipment
grounding conductor can result in a risk of electrical shock,
Check with a licensed electrician if you are in doubt as
to whether the appliance is properly grounded,
1.
The washer MUST be grounded,
In the event of
malfunction or breakdown, grounding will reduce
the risk of electrical shock by a path of least resistance
for electrical current,
2.
Since your washer is equipped with a power supply
cord having an equipment-grounding conductor and
a grounding plug, the plug MUSTbe plugged
into an appropriate, copper wired receptacle that is
properly installed and grounded in accordance with
all local codes and ordinances or in the absence of
local codes, with the National Electrical Codes, ANSI/
NFPA 70 (latest edition). If in doubt, call a licensed
electrician. DO NOTcut off or alter the grounding
prong on the power supply cord. In situations where
a two-slot receptacle is present, it is the owner's
responsibility to have a licensed electrician replace
it with a properlygroundedthree
prong grounding
type receptacle.
WATER
SUPPLY
REQUIREMENTS
Hot and cold water faucets MUST be installed within
42 inches (107 cm) of your washer's water inlet. The
faucets MUST be 3/4 inch (1.9 cm) garden hose type
so inlet hoses can be connected. Water pressure MUST
be between
10 and 120 pounds
per square inch
(maximum unbalance pressure, hot vs. cold, 10 psi.)
Your water department can advise you of your water
pressure.
DRAIN
REQUIREMENTS
1.
Drain capable of eliminating 17 gals (64.3 L) per
minute.
2.
A standpipe
diameter
of 1-1/4
in. (3.18 cm)
minimum.
3.
The standpipe height above the floor should be:
Minimum height:
24 in. (61 cm)
Maximum height:
96 in. (244cm)
))
BACK
96 in,
(244 cm)
24 in.
(61 cm)
Min.
NOTE:
Drain hose attached to the washer can reach a 58
in. (147 cm) high standpipe. For higher standpipe
use hose P/N 131461201,
available
from an
authorized parts distributor.
If drain is less than
24 in. (61 cm), install a siphon break kit, available
at your local hardware store.