ElEctRical opERatioN: chEcKiNg thE thERmoStat aND hEatER
1
Pull out the plug from the wall socket.
2
Remove the plastic cover on the thermostat.
Remove electrical cables from the thermostat.
3
By-pass the thermostat by cennecting the cables using tape or sticking plaster.
4
Make sure to insulate the metal ends completely.
5
Push the plug into the wall socket and put the refrigerator on test for at least 3–4 hours.
If the refrigerator gets cold the thermostat should be replaced.
6
7
If the cooling unit does not get warm, replace the heater.
!
When finished, do not forget to put
the wires back on the thermostat.
chEcKiNg thE thERmo-ElEmENt
1
Check that the joint [A] between thermo-element and flame failure device is tightened properly.
2
Check that the tip [B] of the thermo-element is located in the flame.
3
Check the flame failure device (below).
www.sibir.com
!
Do not attempt this procedure without the
proper knowledge of electrical components.
3
A
Insulate metal ends
completely. Use tape
or sticking plaster.
4
B
copyright © sibir international
10