Donning and use of the hood
• Tear open the sealed bag to remove the hood by opening the pouch (Fig. 1).
• Slip the hood over the head whilst holding the filter in one hand in order to position the interior mask.
• The elastic strap allows the interior mask to fit automatically into place (Fig. 2)
• Leave the contaminated area as quickly as possible, without hurrying and breathing normally.
• Before each entrance in the risk area, check the transport bag for damages and seal's presence.
• Check that no hairs are caught between the face and the inner mask. The seal of the filtering escape device is also affected by size and facial structure of
the user, e.g. beard hair, deep scars, sideburns, etc.
• Breathe slowly and regularly.
• Do not remove the filtering escape device before leaving the contaminated area.
• When removing the hood, take all necessary precautions to avoid inhaling the dust or contaminant retained on the external surface of the filtering escape
device.
• After use, it is mandatory to replace the filter and recondition the hood in an airtight seal aluminium bag.
• Don't use the hood if the airtightness is not achieved. See maintenance instructions.
• Never alter or modify the hood.
After use
• Take off the OPENGO.
• Clean the mask
Disposal
Respiratory filters should be disposed of as hazardous waste corresponding to your local hazardous waste disposal regulations.
Technical data
Dimensions:
28 x 16 x 10 cm
Weight:
710 g
Maximum life time:
12 years (with 1 filter change after 6 years if apparatus was never used).
MAINTENANCE AND INSPECTION OPERATIONS _______________________________________________________________________________________________________
Maintenance must only be made by HONEYWELL RESPIRATORY SAFETY PRODUCTS, or by personnel authorized and trained by HONEYWELL RESPIRATORY
SAFETY PRODUCTS.
Maintenance has to be made:
• After using the apparatus for an escape
• After accidental opening of the apparatus
• After 6 years storage.
In any case, the apparatus must be disposed after 12 years.
Please contact HONEYWELL RESPIRATORY SAFETY PRODUCTS to request a maintenance or get the contact for the nearest maintenance service center.
LIMIT OF MANUFACTURER'S GUARANTEE _____________________________________________________________________________________________________________
The OPENGO carried the HONEYWELL RESPIRATORY SAFETY PRODUCTS standard guarantee. In compliance with our own manufacturer's instructions, in-
spection and maintenance of the OPENGO must only be carried out by qualified professionals, trained and approved by our technical department. Use only
replacement parts supplied by the manufacturer and always follow the inspection and maintenance rules specified in these instructions.
APPROVALS ____________________________________________________________________________________________________________________________________________
Product complies with the European Parliament and Council Regulation 2016/425/EU for Personal Protective Equipment and subsequent amendments.
Production process is subject of conformity to type based on quality assurance set out in Module D of PPE Regulation.
Detailed information about the statutory and regulatory requirements applicable to this product is available in the attached Declaration of Conformity (also
available at http://www.honeywellsafety.com/europe).