TECHNICAL DATA
Display:
Display refresh rate:
Resolution:
Zero switch-off:
Precision:
Measurement units:
Nm
1.5 - 30 Nm
ü
10 - 350 Nm
ü
50 - 1100 Nm
ü
Hold time auto-reset:
AC power adapter:
Power consumption:
Operating temperature range:
Storage temperature range:
Max. operating humidity:
Environment:
Max. rotational load in operation:
Materials / design of housing:
Electromagnetic compatibility:
Low Voltage Directive:
NOTE:
28
Technical data
3
128 x 64 pixel RGB backlit LCD
5 readings per second (5Hz)
4 digits
None
See calibration certificate
(nom. ±1% of the measured value)
Available units depending on the respective torque
tester
dNm cNm kgf·m kgf·cm gf·m lbf.ft lbf.in ft.lb
ü
ü
ü
ü
ü
ü
ü
ü
1, 2 or 3 seconds (adjustable)
90 to 264 volts AC at 47 - 63 Hz input (world)
Includes replaceable mains plug
Energy efficiency level VI
5V, 1,000 mA DC USB A output plug
0.5 W – maximum
0°C to +50°C
-20°C to +70°C
85% relative air humidity at 30°C
IP 40, for enclosed spaces in a lightly polluted
industrial environment
120% of the nominal rotational load
Powder-coated aluminium housing
Measuring shaft made of stainless steel
Developed in accordance with EN 61326-1.
Developed according to EN 61010-1.TRANSIENT
OVERVOLTAGE up to
OVERVOLTAGE CATEGORY II
Subject to technical changes
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
in.lb ozf.in in.oz
ü
ü
ü
ü
ü