INSTALLATION: SINGLE-ENDED
Single Lamp
STEP 1: On the Side A lampholder, connect Line (L) and Neutral N(L1) AC wires to the corresponding pins marked (L) and N(L1)
on the endcap. If only one lamp is being installed, proceed to STEP 3.
Multiple Lamps
Follow STEP 1 to connect the first lamp.
STEP 2: Connect the terminals on the powered lampholder of the first lamp to the matching terminals on the powered
lampholder of the second lamp with Line and Neutral wires as shown. Continue daisy-chain connections for each lamp.
(L) LINE
STEP 3: Complete all electrical connections with appropriate connectors and replace wiring compartment cover.
IMPORTANT: There should not be any exposed wires from sockets remaining unconnected.
STEP 4: Install the lamps, making sure Side A is installed in the lampholders wired to the Line and Neutral. Install any lens
or diffuser as applicable.
STEP 5: Turn power on. Installation is complete.
INSTALLATION: DOUBLE-ENDED
Remove Existing Fluorescent System
• Disconnect power from fixture, and remove fluorescent lamp(s).
• Remove lens and wiring compartment, if applicable.
• Cut all wires connected to the ballast (as shown in diagrams A, B and C on page 2) and remove ballast.
• Identify what type of lampholders are in the fixture. Double-Ended wiring installations can be used with shunted G13 or
non-shunted G13 lampholders (see Figures 1 and 2 on page 2).
Single Lamp
STEP 1: From AC wires, connect Line (L) to Side A lampholder and Neutral N(L1) to Side B lampholder. If only one lamp is
being installed, proceed to STEP 3.
Shunted Lampholders
(L) LINE
Multiple Lamps
Follow STEP 1 to connect the first lamp.
STEP 2: Connect the terminals from the first lamp to the matching terminals on the lampholder of the second lamp with
Line and Neutral wires as shown. Continue daisy-chain connections for each lamp.
Shunted Lampholders
(L) LINE
STEP 3: Complete all electrical connections with appropriate connectors and replace wiring compartment cover.
IMPORTANT: There should not be any exposed wires from sockets remaining unconnected.
STEP 4: Install the lamps and any lens or diffuser as applicable.
STEP 5: Turn power on. Installation is complete.
(Continued)
NEUTRAL N(L1)
NEUTRAL N(L1)
NEUTRAL N(L1)
(L)
120-277V
N(L1)
(L)
120-277V
N(L1)
Non-Shunted Lampholders
(L) LINE
Non-Shunted Lampholders
(L) LINE
3
NEUTRAL N(L1)
NEUTRAL N(L1)