Descargar Imprimir esta página

PROMAT CM 100 Instrucciones De Empleo página 30

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Frequency measurement (with the clamp-on ammeter)
Measuring range
600 Hz
1 kHz
>1 kHz
Measuring range: 10 Hz ~ 1 kHz
Input range: >1 A RMS AC
Frequency measurement (with the input socket (V))
Measuring range
600 Hz
6 kHz
10 kHz
>10 kHz
Measuring range: 10 Hz ~ 10 kHz
Input voltage: > 0.2 V RMS AC
Input impedance: 10 M
Duty cycle measurement (Duty Cycle/%)
Measuring range
10 – 95 %
Clamp-on ammeter: - Frequency range: 10 Hz ~ 1 kHz
Measurement socket: - Frequency range: 10 Hz ~10kHz
Resistance measurement
Measuring range
600 
6 k
60 k
600 k
6 M
60 M
Off-load voltage: 0.4 V
- Input current: >1 A RMS AC
- Maximum input current: 600 A AC
- Input voltage: >0.2 V RMS AC
- Input impedance: 10 M
- Maximum input voltage: 600 V RMS AC
Resolution
0.1 Hz
1 Hz
1 Hz
Resolution
0.1 Hz
1 Hz
10 Hz
10 Hz
Resolution
0.1 %
Resolution
0.1 
0.001 k
0.01 k
0.1 k
0.001 M
0.1 M
30
Tolerance
± 1.5 + 5 digit
Only as reference
Tolerance
± (1.5 % + 5 digits)
Only as reference
Tolerance
± 3.0 %
Tolerance
± (1.2 % + 2 digits)
± (2.0 % + 5 digits)

Publicidad

loading

Este manual también es adecuado para:

4000828966