Descargar Imprimir esta página

EINHELL TE-AC 110/6 Silent Plus Manual De Instrucciones Original página 16

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
At low temperatures below +5°C, sluggish-
ness may make starting difficult or impossib-
le.
6.3 Fitting the transport handle (9)
Screw the transport handle (9) to the compressor
as shown in fi gures 5 to 6.
6.4 On/Off switch (8)
To switch on the compressor, pull out the On/Off
switch (8).
To switch off the compressor, press the On/Off
switch (8) in again. (Figure 2).
6.5 Setting the pressure (Fig. 1,2)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be drawn from the
quick-lock coupling (5).
6.6 Setting the pressure switch
The pressure switch is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Pull out the power plug before doing any
cleaning and maintenance work on the
equipment.
Warning!
Wait until the compressor has completely
cooled down. Risk of burns!
Anl_TE-AC_110-6_Sil_Pl_SPK13.indb 16
Anl_TE-AC_110-6_Sil_Pl_SPK13.indb 16
GB
Warning!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
Warning!
After use, always switch off the equipment
immediately and pull out the power plug.
8.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could at-
tack the plastic parts of the equipment. Ensu-
re that no water can seep into the device. The
ingress of water into an electric tool increases
the risk of an electric shock.
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
8.2 Condensed water (Fig. 1)
Important! To ensure a long service life of the
pressure vessel (2), drain off the condensed wa-
ter by opening the drainage cock (11) each time
after using.
Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure
vessel. If you discover any damage, please con-
tact the customer service workshop.
8.3 Safety valve (10)
The safety valve has been set for the highest per-
mitted pressure of the pressure vessel. It is prohi-
bited to adjust the safety valve or remove its seal.
Actuate the safety valve from time to time to en-
sure that it works when required. To do so, open
the screw cap of the valve while the tank is under
pressure. Once the screw cap has been fully ope-
ned you must pull it to let air escape through the
valve. Then screw the cap fully back in place.
- 16 -
01.02.2024 07:24:24
01.02.2024 07:24:24

Publicidad

loading

Este manual también es adecuado para:

40.206.00