10. Possible causes of failure
Problem
The compressor
does not start.
The compressor
starts but there is no
pressure.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
Anl_TE-AC_110-6_Sil_Pl_SPK13.indb 18
Anl_TE-AC_110-6_Sil_Pl_SPK13.indb 18
GB
Cause
1. No supply voltage.
2. Insuffi cient supply voltage.
3. Outside temperature is too low.
4. Motor is overheated.
1. The non-return valve (3) leaks.
2. The seals are damaged.
3. The drainage cock for condensati-
on water has a leak.
1. The hose connections have a leak.
2. A quick-lock coupling has a leak.
3. Insuffi cient pressure set on the
pressure regulator.
- 18 -
Solution
1. Check the supply voltage, the power
plug and the socket-outlet.
2. Make sure that the extension cable
is not too long. Use an extension
cable with large enough wires.
3. Never operate with an outside tem-
perature of below +5° C.
4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
1. Have a service center replace the
non-return valve (3).
2. Check the seals and have any da-
maged seals replaced by a service
center.
3. Check the drainage cock and repla-
ce if necessary.
1. Check the compressed air hose and
tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
3. Increase the set pressure with the
pressure regulator.