APPENDIX
MODEL
INPUT PARAMETERS
Nominal DC Power [kW]
Max. Recommended DC Power [kW]
Operating Input Voltage Range [V]
Full Power MPPT input voltage range (symmetrical load) [V]
Full Power MPPT input voltage range (asymmetrical load) [V]
Absolute Max. Input Voltage [V]
Activation voltage "Vstart" [V]
No of independent MPPT trackers
Max. Input Power, each MPPT [kW]
No. of DC Inputs
Max. DC Current, each MPPT [A]
Absolute Max. input short circuit current (ISC) [A]
DC Connection
Max. inverter Backfeed Current to the array [A]
INPUT PROTECTION
Reverse polarity protection
Fuse rating, each input (-FS suffix versions only) [A]
Thermally Protected DC side varistor
PV array Insulation Control
DC Switch (-S/-FS suffix versions only)
OUTPUT PARAMETERS
Nominal AC Power [up to 50°C, kW]
Max. AC Power [kW]
AC Grid Connection
Nominal AC Voltage [V]
AC Voltage Range [V]
Nominal AC Frequency [Hz]
AC Frequency Range [Hz]
Max. AC Line Current [A]
Maximum output fault current (a.c. A, peak and duration or RMS)
AC Connection
Line Power Factor
Inrush Current (a.c. A, peak and duration)
AC Current Distortion [THD%]
OUTPUT PROTECTION
AC side varistors
Ground fault protection (AC + DC leakage current)
ENVIRONMENTAL PARAMETERS
Cooling
Ambient Temp. Range [°C]
Opertaing Altitude [m]
Acoustical Noise [dBA]
Environmental IP Rating
Relative Humidity
Environmental pollution classification for external enviroment
MECHANICAL
Dimensions [H x W x D]
Overall Dimensions (with flanges) [H x W x D]
Weight [kg]
Protective Class
Overvoltage Category in accordance with IEC 62109-1
(*) Limited to 16A for UK G83/1 Version.
APPENDIX E
TECHNICAL DATA
PVI-3.0-TL-OUTD
3,12
3,5
160-530
200-530 (@ 2kW) / 112-530 (@ 1,12kW) 190-530 (@ 3kW) / 90-530 (@ 0,75kW) 190-530 (@ 3kW) / 90-530 (@ 1,38kW)
200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input)
2
2 ( 1 each MPPT )
10
12,5
4 (2 positive, 2 negative)
Weidmüller / Multicontact Ø 4mm (male - positive input + female - negative input); Mating cable connector included
Conductor cross section: 4-6mm2 (AWG12-10)
Cable Ø w/insulator: 5,5-9mm (Multicontact), 5,5-7,5mm (Weidmüller)
NA
3
3,3
180-264 (may vary to comply with regulations in each country)
47-53 (may vary to comply with regulations in each country)
14,5 ( 16 short circuit )
Conductor cross section: Solid 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6
Cable Gland: M25 - Cable Ø: 10-17mm
<3,5% at rated power with sine wave voltage
-25 / +60 (out. power der. above 50 °C) -25 / +60 (out. power der. above 55 °C) -25 / +60 (out. power der. above 50 °C)
6 - APP
PVI-3.6-TL-OUTD
3,75
4,15
0,7xVstart - 580
120-530
600
2
3
16
20
Negligible
Yes
NA
4 ( 2 for each MPPT )
according to local standard
Integrated (Rating : 600Vdc / 25A)
3,6
4
single phase ( Live, Neutral, PE )
230
50
17,2(*) ( 19 short circuit )
<25 A rms (100ms)
Screw terminal block
>0,995
Negligible
2 ( Live - Neutral / Live - PE )
according to local standard
Natural cooling
2000
< 50 @ 1mt
IP65
0-100% condensing
3
547 x 325 x 210
689 x 325 x 222
17
I
II (DC Input); III (AC Output)
PVI-4.2-TL-OUTD
4,375
4,82
140-530
3 ( 2 for MPPT1, 1 for MPPT2 )
6 (3 positive, 3 negative)
NA
4,2
4,6
20 ( 22 short circuit )