Descargar Imprimir esta página

Kenmore ELITE 233.54363200 Manual De Uso Y Cuidado / Instalacion página 10

Campana de cocina

Publicidad

Idiomas disponibles

Idiomas disponibles

Adjust the width of the flue mounting
bracket
assembly to equat the inside width of decorative flue.
Insert and tighten mounting
screws to hold bracket
width.
FLUE MOUNTING
BRACKET
MOUNTBNG
SCREWS
2. Use mounting
screws and wall anchors
to secure
flue mounting bracket assembly to the ceiling as
shown.
MOUNTBNG
SCREWS
i
3. Measure the distance from the top of the hood outlet
to the ceiling o and add 6 inches.
4. Cut a piece of 5" round flexible metallic duct (not
included) to the length determined in Step 3. Attach
flange to bottom of flexible duct and secure with duct
tape.
5. Attach top of flexible duct to air baffle and secure with
duct tape.
6. Connect the flange to the hood outlet.
7. Turn upper flue section
upside down so air vents
are at the top. Slide upper flue section into tower flue
section.
8. Set flue assembly on hood, with top tilted away from
wall. Align (4) holes in baffle with (4) holes in top flue
section.
9. Attach baffle to upper flue section with (4) screws
(included). Use a short screwdriver.
10. Extend the upper flue section to the ceiling and
secure to upper bracket with (2) mounting screws.
l
AIR VENTS
UPPER
FLUE
SECTION